The battery charger does not need any maintenance. To ensure optimum performance from the equipment, once a
year check the cables and the electrical connections.
TECHNICAL DATA
MODEL
SBC 700 NRG FR
SBC 1100 NRG FR
SBC 750 NRG FR
SBC 950 NRG FR
OUTPUT CHARACTERISTICS
Maximum output current
(1)
60 A
(
)
80 A
(
)
30 A
(
)
40 A
(
)
Charge absorption voltage
14,1 Vdc EL open
14,4 Vdc EL sealed / gel/ AGM
28,2 Vdc EL open
28,8 Vdc EL sealed / gel / AGM
Charge float voltage
13,4 Vdc EL open
13,8 Vdc EL sealed gel - 13,6 Vdc AGM
26,8 Vdc EL open
27,6 Vdc EL sealed gel - 27,2 Vdc AGM
DC absorption from the batteries
(2)
< 3,5 mA
< 5 mA
Residual ripple
(3)
< 100 mV RMS
Charging characteristics
Automatic in three stages IUoU
Number of outputs
(4)
3
INPUT CHARACTERISTICS
Supply voltage
264÷83 Vac, with power reduction under 108 Vac
Frequency
45÷66 Hz
Maximum absorption (230/240 Vac)
(5)
3,9 A
5,3 A
3,8 A
5,2 A
Maximum absorption (120 Vac)
(6)
7,8 A
10,7 A
7,6 A
10,5 A
Power factor (cos
ϕ
)
(5)
1,00
Efficiency
(5)
≥
88%
≥
90%
PROTECTION
Reverse polarity
(7)
Yes, through fuse
Overload
Yes
Output short circuit
Yes
Overvoltage in output
(8)
Yes
Overheating
Yes
Battery overtemperature
Yes, optional
AMBIENT CHARACTERISTICS
Operating temperature
-15 ÷ +70 °C, with linear power reduction over +50 °C
Cooling
Quick Smart Fan (Forced, with variable fans speed)
Noisiness (acoustic)
< 51 dbA @ 1 m (42 dbA @ 1 m in silent mode)
Humidity
Max. 95% RV without condensation
CASE
Material
Aluminium - Cycoloy
®
Dimensionis (WxHxD)
243 x 479 x 116 mm
Weight
5,3 kg
5,6 kg
5,3 kg
5,5 kg
GENERAL
CAN BUS interface
Yes
Charge compensation
Yes, optional (max 128 battery temperature sensors)
Safety standard
EN 60335-2-29
EMC Standard
EN 55022/B - FCC TITLE 47 PART 15 SUBPART B CLASS B
(1)
Maximum rated value at normal use or in short circuit.
(2)
With battery charger not supplied by the AC network and with disabled monitor mode.
(3)
At 50% of the output current on resistive load.
(4)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed the maxi-
mum nominal value of the equipment.
(5)
With supply voltage equal to 230 Vac and output current equal to the maximum nominal value.
(6)
With supply voltage equal to 120 Vac and output current equal to the maximum nominal value.
(7)
Protection may be inefficient in some operative conditions.
(8)
Software/hardware double-check.
Cycoloy
®
is a registered trade mark of GE Plastics.
Содержание SBC NRG Series
Страница 2: ......
Страница 36: ...36 SBC NRG MEDIUM REV001A SBC MEDIUM POWER NRG DIMENSIONI DIMENSIONS mm 220 463 479 243 116...
Страница 37: ...NOTES...
Страница 38: ...SBC NRG MEDIUM REV001A NOTES...
Страница 39: ...39 SBC NRG MEDIUM REV001A...