(1)
Maximum value at normal use or in short circuit.
(2)
At maximum output current on resistive load.
(3)
Each output can supply the maximum value of nominal current. The sum of the currents supplied from each output can not exceed
the maximum nominal value of the equipment.
(4)
With supply voltage as specified and output current equal to the maximum nominal value
(5)
Protection may be inefficient in some operative conditions.
(6)
Software/hardware double-check.
Cycoloy
®
is a registered trade mark of GE Plastics.
MAINTENANCE
The battery charger does not need any maintenance. To ensure optimum performance from the equip-
ment, once a year check the cables and the electrical connections.
TECHNICAL DATA
MODEL
SBC1100 ADV PLUS FR
SBC1450 ADV PLUS
SBC1950 ADV PLUS
OUTPUT CHARACTERISTICS
Maximum output current
(1)
Charge absorption voltage
Charge float voltage
Residual ripple
(2)
Charging characteristics
Number of outputs
(3)
80 A
60 A
80 A
14,1 Vdc (14,4 Vdc GEL)
28,2 Vdc (28,8 Vdc GEL)
13,5 Vdc (13,8 Vdc GEL)
27,0 Vdc (27,6 Vdc GEL)
90mV RMS max
Automatica a tre stadi IU0U
3
Yes, through fuse
Yes
Yes
Yes
Yes
Yes, optional
280÷83 Vac, with power
280÷150 Vac, with power reduction under 195 Vac
reduction under 97 Vac
45÷66 Hz
6,4 A
8,9 A
11,9 A
12,9
A
-
1
-20 to +70 °C, with power reduction over +50 °C
Automatic , by variable speed cooling fan
Max. 95% RV without condensation
Yes, digital (CAN BUS)
EN 60335-2-29
EN 55022/A
Stainless steel - Cycoloy
®
Polished steel - OR5066
272 x 495 x 127 mm
7,1 Kg
INPUT CHARACTERISTICS
PROTECTION
Supply voltage
Frequency
Maximum absorption
(4)
(230 Vac)
Maximum absorption
(4)
(115 Vac)
Power factor (cos
ϕ
)
CASE
Material
Colour
Dimensions (WxHxD)
Weight
Reverse polarity
(5)
Overload
Output short circuit
Overvoltage in output
(6)
Overheating
Battery overtemperature
AMBIENT CHARACTERISTICS
Operating temperature
Cooling
Humidity
GENERAL
Connector for remote panel
Safety classification
EMC class