44
EN
INSTALLATION AND USE MANUAL
QUICK MC²X 16k - 16k LV
- REV001E
16k - 16k LV
8 - Electrical connection
8.0 - Connection system devices
AC DYNAMIC CONTROL MC
2
X - DRIVER
Gyroscope control and management unit.
Install the AC DYNAMIC CONTROL MC
2
X driver in a dry, ventilated place in order to enable the stabilizer’s operation at full
power.
The driver is supplied with a drill template.
THE DRIVER MUST BE INSTALLED AT A SUITABLE DISTANCE FROM THE STABILIZER TO ENSURE THAT, DURING
FULL-SPEED OPERATION, THE HOT AIR FLOW COMING FROM THE STABILIZER DOESN’T JEOPARDISE THE
DRIVER’S FUNCTIONING.
• The driver must be installed with the wire connections at the bottom.
• It is recommended to install this device in a vertical position in order to facilitate its cooling.
• Fix to the support surface with suitable screws that can support its weight without causing structural damage to the boat.
• The driver (excluding the side to be fixed) must be placed at least 5 cm. (2 in.) away from walls or objects.
Wiring must be performed following the instructions outlined in section 8.2
RC REMOTE CONTROL MC
2
X
The
RC Remote Control
MC
2
X touch
is the dashboard device that is used the stabilizer monitoring.
The panel features an LCD display to access the controls to turn the stabilizer on/off,
and to display its status and correct operation (multi-station compatible).
Connection by means of a DB connection cable (CAN-BUS).
RC MC
2
X
is supplied a drill template. Available in sizes 4" and 5" graphic display. IP66.
* Not supplied
The stabilizer is supplied already pre-wired; each connector has a tag with instructions aimed at facilitating electrical
connections.
DO NOT MODIFY THE OUTPUT POSITION OF THE STABILIZER’S PREWIRED CABLES.
MAKE SURE TO CONNECT THE DRIVER AND THE STABILIZER WITH THE SAME SERIAL NUMBER.
Operation range: 196-260 Vac (single-phase) - Frequency 50/60 Hz.