Nozzle 3
Once the nozzle 3 comes to run the program, the output is in conducting
state, or else not.
Nozzle 4
Once the nozzle 4 comes to run the program, the output is in conducting
state, or else not.
Ready flag
When the unit comes into the normal ready state, the output is in
conducting state, namely, once receiving the “START” signal, it comes
to run. And it closes the output after running.
Alarm flag
When set the mode as alarming, once it detects the abnormal state, the
output is in conducting state, or else not.
Working flag
When the unit comes into the working state, the output is in conducting
state, or else not.
Work End flag
After t finishing the process, the output is keeping in conducting state
200ms, or else not.
Cylinder
Once the unit comes to run the cylinder process, the output is in
conducting state, control cylinder motion, or else not.
Clean output
Once the unit comes to run the clean process, the output is in conducting
state, do the clean (blowing or revolving brush), or else not.
Pause flag
The condition of pause BTN
Left light flag
The condition of left light on key box
Right light flag
The condition of right light on key box
Note:
The function settings of input & output cannot be accessed by the operator. It
can only be operated by the manufacturer.
Will not give advanced information if some functions are changed.