background image

 

 

 

*Keys on the right side 

1.

 

Press the key on the top of the rocker “PCB MOVE CONTROL” 

and when swinging the rocker leftward or rightward, the PCB fixture 

will do the corresponding movement, leftward or rightward. When 

swinging the rocker onward or backward, the PCB fixture will do 

the corresponding movement, onward or backward.   

2.

 

If do not press the key on the top of the rocker and swing the rocker, 

the pad sucking the chip can do turn 360

°

1.

 

Only when the aligning arm is out, the boons “RED”& “WHITE” 

and the keys “ZOOM” & “FOCUS” can work. 

2.

 

The “WHITE” knob adjusts the brightness of the bottom white light. 

3.

 

The “RED” knob adjusts the brightness of the top red light. 

4.

 

“ZOOM+”&“ZOOM-” keys zoom the image. 

5.

 

“FOCUS+” & “FOCUS-” for camera focusing. 

 

Infrared heater switch: controlling the corresponding heater is on 

or off. The middle two heaters (red mark) are on. 

 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 

 
 
 
 

 

 
 
 

1.

 

START

: in standby mode, click it into the soldering or 

de-soldering process. 

2.

 

STOP

: in the soldering or de-soldering process, click it to exit the 

current process and the heating arm will move upwards.   

3.

 

HEAD-CONTROL 

△ ▽

: Control the movement of the top  

sirocco-heating arm, upward or downward.

 

4.

 

CAMERA

: Click it to make the aligning arm moving out and 

open the camera. It can do the alignment.

 

5.

 

SUCKER

: Make the sucking pad suck the chip. 

 

6.

 

VACUUM

: Click it to open the vacuum bump.

 

* Note:    In the flow of soldering or de-soldering, the keys (CAMERA, SUCKER, VACUUM and COOL 

FAN) cannot work.

 

 

7.  Aligning

 Arm Instruction

 

Aligning arm is used for the element alignment. In the aligning arm, there is a camera which transmitting the 

information by video cord and then displaying the image about the soldering point in the PCB and element 

pins below the nozzle. Users can observe element alignment by adjusting function keys. 

 

Page 7 

Содержание BGA2100

Страница 1: ...QUICK BGA 2100 ...

Страница 2: ...CK BGA2100 Rework System with 60 60mm optics aligning prism big BGA alignment can see clearly and the aligning lens are controlled by the step motor and the chip slave is above the lens The PCB fixture is square and the maximum size is 550 450mm the width of the left and right arms can be adjusted and the abnormity knightheads can be fixed on the arms And the bottom knighthead is connecting with t...

Страница 3: ...an be ordered 2 2 Technical Parameter MAIN INTERFACE T0 Valve temperature and T0 TIR Only when the temperature of the bottom infrared heater up to the T0 the top and bottom hot air heater comes to heat VT The setting airflow of the top hot air VB The setting airflow of the bottom hot air TY Select solder flow or de solder flow sold or desold Top The setting sirocco temperature of the top in the D1...

Страница 4: ...et the communication baud rate and the default value is 19200 HEAD DOWN MODE When the value is 0 the heater head adjusts automatically the distance between it and the chip when touching the chip When the value is not 0 the value is the downward moving distance of the heater head The parameters in the data interface can be set in the advanced interface of the BGA software The PASSWORD s function is...

Страница 5: ...nits are turn off or not Connect the power cord to the power socket Connect the RS 232 cord to the RS 232 socket in PC if you use the BGA software Connect the video line of the external LCD to the VIDEO OUT socket There are four VIDEO OUT sockets in the PC and each socket to the different communication port Connect the K type sensors optional to the external sensor s socket in the front VIDEO inpu...

Страница 6: ...able on the software or on the small LCD refer to MIAN INTERFACE The bottom preheater 1 The maximal heating power of the bottom infrared heater is 3200W and the maximal temperature is 500 2 The middle two heaters are kept on and the other six heaters can be controlled by the switches 5 PCB Fixture and movement controlling Bottom preheater and the PCB fixture The adjustable infrared heater can prov...

Страница 7: ... pad sucking the chip can do turn 360 6 Fix anomalistic PCB with anomalistic knightheads and bottom fixtures for preventing subside Anomalistic knightheads Bottom fixtures for preventing subside 6 keys instructions Keys on the left side Page 6 The six keys can control the parameters setting of the MAIN interface SET click it into the setting mode SAVE click it to save the changed parameters and ex...

Страница 8: ...ing heater is on or off The middle two heaters red mark are on 1 START in standby mode click it into the soldering or de soldering process 2 STOP in the soldering or de soldering process click it to exit the current process and the heating arm will move upwards 3 HEAD CONTROL Control the movement of the top sirocco heating arm upward or downward 4 CAMERA Click it to make the aligning arm moving ou...

Страница 9: ...ess SUCKER key to the state of the chip sucking and the nozzle will suck the chip automatically Press START key to the state of the chip pasting and the nozzle will paste the chip automatically Turn the rocker when optics alignment to make the BGA sucked by the nozzle turning until the stannum ballpoint in the BGA is superposable with the cuprum point in the PCB During the process make the rocker ...

Страница 10: ...sword The system pops up the following dialog box Note the password can protect the MCU s parameters from change by un authorizing person c Main interface Tab 1 The main interface s function is to operate the software The data cannot be changed at the screen 2 It can select soldering or desoldering process and select one flow saving in the PC 3 At the bottom of the screen it will display the runni...

Страница 11: ...rameter adjustment interface 2 At this interface it can change the parameter values in the all flows and save them 3 First click process select and then pop up a interface saving flow Select a flow such as U1 medl and then change this flow s parameter values 4 After change the values click the parameter s save to save the parameter values and click the save curve to save the flow s curve into the ...

Страница 12: ... the curve it will show the real time temperature and time of the point 3 Click the print button to print the current flow s information and curve 4 Click the delete button to delete the file showing g Advanced set Tab 1 Click Advanced set tab it will display the advanced setting interface 2 All the functions of the software can be set in this interface including 1 Password setting 2 K type sensor...

Страница 13: ...the sirocco nozzles 3 Select parameters or set the parameters with keys A Select the required flow if need to modify the parameter input the password before performing relevant operation B Select solder working mode C No change in communication speed and press SAVE button to save and exit to MAIN surface D System starts working after pressing START running the select flow 4 LCD will display series...

Страница 14: ...s to Keys Instructions 6 Unscrew the PCB Fixing Knobs on the PCB Fixture to open PCB Clamp Bar Fix the soldered PCB on the PCB Fixture and adjust PCB s position to the below of the aligning arm Make the LCD display the image of soldering point and make the images of soldering point and component in the same center point It is convenient for adjusting After roughly adjusting screw the Fixture Fixin...

Отзывы:

Похожие инструкции для BGA2100