INSTALLATION AND USE MANUAL - QUICK B3 SERIES 

WATER 

 

Heater

 - REV001A

4.2.0 - Cautions for use

Before connecting the equipment, make sure that cables are not live.

Never switch on the electric element if the water heater is NOT filled with water, otherwise the 

heating element could be irreversibly damaged and the protection devices will not work properly.

WARNING

: if the power cable is damaged, have it replaced at a Quick® service centre. To avoid 

accidents, the equipment must only be opened by authorised personnel. The warranty will be void if 

the equipment is opened by unauthorised personnel.

4.2.1 - DC power supply of the equipment

The equipment is provided with a box for DC network connections.

For connections to the DC network, see fig. 3. Before supplying power to the water heater, make sure that its 

operating voltage corresponds to that supplied by the DC network.

An equipment ON/OFF switch and a 30A fuse must be installed in the electrical system. The insulation material 

between the contacts of the connections to the DC network must be at least 3 mm.

Connections to the DC network must be made in accordance with the national standards on electrical systems.

4.2.2 - AC power supply of the equipment

The equipment is already provided with a power cable for the AC network. For connections to the AC network, 

see figure 3. Before supplying power to the water heater, make sure that its operating voltage corresponds to that 

supplied by the AC network. 

A double pole switch must be installed in the electrical system to turn the equipment on and off and a fuse suitable 

for its absorption. The insulation material between the contacts of the connections to the AC network must be at 

least 3 mm. Connections to the AC network must be made in accordance with the national standards on electrical 

systems.

4.2.3 - AC thermostat setting

The thermostat factory-set temperature value is 60°C.

If you wish to change this value, follow the procedure below:

• interrupt the power supply.

• Remove the protection cover to reach the thermostat.

• Use a screwdriver to turn the thermostat knob and set the desired temperature value.

• 

Refit the protection cover.

• Restore the power supply.

The thermostat regulates the water temperature 

only when operating with electric element.

5 - Wiring diagram

THERMOSTAT TEMPERATURE 

SETTING KNOB

4 - Installation / Use

PROTECTION 

COVER

Содержание B3

Страница 1: ...l seguente manuale o sull etichetta alloggiata sul prodotto ES Otros idiomas disponibles escaneando el c digo QR en la parte posterior de este manual o en la etiqueta del producto FR Autres langues di...

Страница 2: ......

Страница 3: ...ons for the installer 6 4 Installation Use 7 4 0 Installation requirements 7 4 1 Installation procedure 7 4 2 Use 7 4 2 0 Cautions for use 8 4 2 1 DC power supply of the equipment 8 4 2 2 AC power sup...

Страница 4: ...ing durability and resistance over time Heat exchanger with a large exchanging surface Possibility of producing hot water even with the electric element complete with adjustable and safety thermostat...

Страница 5: ...VAC 220 VAC 110 VAC 110 VAC 220 VAC Electric element power rating 500 W 600 W 1200 W 500 W 600 W 1200 W 500 W 600 W 1200 W Fittings diameter 1 2 1 2 1 2 Weight 2 Kg 8 5 10 5 11 7 Lb 18 7 23 1 25 8 1 1...

Страница 6: ...al capabilities Quick SpA shall not be held liable for direct or indirect damage caused by improper use of the equipment Never switch on the electric element if the product is not filled with water ot...

Страница 7: ...able for installation C Make the hydraulic connections for the tap hot water input and output and the engine cooling circuit to the heat exchanger in models featuring it as shown in figure 2 page 9 Th...

Страница 8: ...the DC network must be at least 3 mm Connections to the DC network must be made in accordance with the national standards on electrical systems 4 2 2 AC power supply of the equipment The equipment is...

Страница 9: ...ICK B3 SERIES WATER Heater REV001A 5 0 B3Series hydraulic connection FIG 1 FIG 2 5 1 Hydraulic connection diagram 12 V ENGINE COOLING LIQUID HOT TAP WATER OUTPUT COLD TAP WATER INPUT TAP WATER TANK WA...

Страница 10: ...Wiring diagram 5 2 AC connection diagram FIG 3 FIG 4 1 L 2 N N L T 105 2 1 R E S E T S A F E T Y AC NETWORK NEUTRAL AC NETWORK LIVE THERMOSTAT TEMPERATURE SETTING KNOB RESET BUTTON PHASE NEUTRAL EART...

Страница 11: ...Periodically check the efficiency of the electrical system 6 1 B3Series AC maintenance WARNING Quick water heaters only AC model are equipped with a double thermostat with manual reset that cuts off t...

Страница 12: ...provided for by local regulations for this product category Some parts of the product may contain pollutants or hazardous substances that if dispersed may be harmful to the environment and human heal...

Страница 13: ...ELEMENT KIT 500W 220V FVSLRSB05220A00 2D OSP ELECTRIC ELEMENT KIT 800W 110V FVSLRSB0811SA00 2E OSP ELECTRIC ELEMENT KIT 800W 220V FVSLRSB0822SA00 2F OSP ELECTRIC ELEMENT KIT 1200W 110V FVSLRSB12110A0...

Страница 14: ...ON AND USE MANUAL QUICK B3 SERIES WATER Heater REV001A H I C D E G B A F F H I C D G E B A B A F G E H I C D B3 15L 4 GAL B3 20L 5 3 GAL B3 25L 6 6 GAL B3 30L 8 GAL B3 40L 10 5 GAL B3 60L 15 8 GAL B3...

Страница 15: ...64 F 304 318 11 31 32 12 1 2 G 320 12 19 32 H 87 3 27 64 I 259 10 13 64 30L 7 9 gal 40L 10 5 gal A 495 19 31 64 623 24 13 32 B 366 14 13 32 C 158 6 7 32 D 75 2 61 64 E 366 14 13 32 F 304 318 11 31 32...

Страница 16: ...p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com B3Series WATER HEATER SERIES B3 REV 001A B3 15 15 12V B3 20 20 12V...

Отзывы: