Quick B3 Скачать руководство пользователя страница 6

B3Series

EN

B3Series

6

INSTALLATION AND USE MANUAL - QUICK B3 SERIES 

WATER 

 

Heater

 - REV001A

2 - Supply and equipment

2.0 - Standard supply and material included in the package

• Water heater

• Floor or wall-mounting brackets

• Various screws and hardware (for assembly) 

• User’s manual 

• Conditions of warranty.

3 - Introduction

BEFORE USING THE PRODUCT, PLEASE READ THIS USER’S MANUAL CAREFULLY. IF IN DOUBT, 

PLEASE CONSULT YOUR QUICK

®

 DEALER.

Warning

 symbol for 

dangerous situations

.

Caution

 symbol to prevent direct or indirect 

damage to the product.

3.0 - Important notes

3.1 - Precautions

• Use the product only for the applications described in this manual. 

• Do not use these products for any other type of operation. 

• Quick

®

 shall not be held liable for direct or indirect damage caused by improper use of the product. 

• Before connecting the equipment, make sure that cables are not live.

• This equipment is not intended for use by people (including children) with reduced physical, sensory 

or mental capabilities. Quick

®

 SpA shall not be held liable for direct or indirect damage caused by 

improper use of the equipment.

• 

Never switch on the electric element if the product is not filled with water, otherwise the heating 

element could be irreversibly damaged.

3.2 - Precautions for the installer

This manual features Warning and/or Caution symbols that are important for safety.

Stick to the given instructions.

This document provides boat manufacturers and nautical equipment installers with instructions 

on how to assemble the water heater and operate it correctly.

CARRY OUT THE INSTALLATION IN GOOD LIGHTING CONDITIONS.

It is advisable to wear suitable clothing and personal protective equipment (PPE). 

The water heater is not suitable for installation in potentially explosive environments and/or atmospheres.

Installation and subsequent inspection or repair work must only be carried out by qualified personnel.

CARRY OUT INSTALLATION/MAINTENANCE WORK MAKING SURE THAT THE PRODUCT IS 

DISCONNECTED FROM THE ELECTRICAL SYSTEM.

Quick accepts no responsibility for inadequate connection of users to the electrical system and 

inadequate safety of the electrical system.

Содержание B3

Страница 1: ...l seguente manuale o sull etichetta alloggiata sul prodotto ES Otros idiomas disponibles escaneando el c digo QR en la parte posterior de este manual o en la etiqueta del producto FR Autres langues di...

Страница 2: ......

Страница 3: ...ons for the installer 6 4 Installation Use 7 4 0 Installation requirements 7 4 1 Installation procedure 7 4 2 Use 7 4 2 0 Cautions for use 8 4 2 1 DC power supply of the equipment 8 4 2 2 AC power sup...

Страница 4: ...ing durability and resistance over time Heat exchanger with a large exchanging surface Possibility of producing hot water even with the electric element complete with adjustable and safety thermostat...

Страница 5: ...VAC 220 VAC 110 VAC 110 VAC 220 VAC Electric element power rating 500 W 600 W 1200 W 500 W 600 W 1200 W 500 W 600 W 1200 W Fittings diameter 1 2 1 2 1 2 Weight 2 Kg 8 5 10 5 11 7 Lb 18 7 23 1 25 8 1 1...

Страница 6: ...al capabilities Quick SpA shall not be held liable for direct or indirect damage caused by improper use of the equipment Never switch on the electric element if the product is not filled with water ot...

Страница 7: ...able for installation C Make the hydraulic connections for the tap hot water input and output and the engine cooling circuit to the heat exchanger in models featuring it as shown in figure 2 page 9 Th...

Страница 8: ...the DC network must be at least 3 mm Connections to the DC network must be made in accordance with the national standards on electrical systems 4 2 2 AC power supply of the equipment The equipment is...

Страница 9: ...ICK B3 SERIES WATER Heater REV001A 5 0 B3Series hydraulic connection FIG 1 FIG 2 5 1 Hydraulic connection diagram 12 V ENGINE COOLING LIQUID HOT TAP WATER OUTPUT COLD TAP WATER INPUT TAP WATER TANK WA...

Страница 10: ...Wiring diagram 5 2 AC connection diagram FIG 3 FIG 4 1 L 2 N N L T 105 2 1 R E S E T S A F E T Y AC NETWORK NEUTRAL AC NETWORK LIVE THERMOSTAT TEMPERATURE SETTING KNOB RESET BUTTON PHASE NEUTRAL EART...

Страница 11: ...Periodically check the efficiency of the electrical system 6 1 B3Series AC maintenance WARNING Quick water heaters only AC model are equipped with a double thermostat with manual reset that cuts off t...

Страница 12: ...provided for by local regulations for this product category Some parts of the product may contain pollutants or hazardous substances that if dispersed may be harmful to the environment and human heal...

Страница 13: ...ELEMENT KIT 500W 220V FVSLRSB05220A00 2D OSP ELECTRIC ELEMENT KIT 800W 110V FVSLRSB0811SA00 2E OSP ELECTRIC ELEMENT KIT 800W 220V FVSLRSB0822SA00 2F OSP ELECTRIC ELEMENT KIT 1200W 110V FVSLRSB12110A0...

Страница 14: ...ON AND USE MANUAL QUICK B3 SERIES WATER Heater REV001A H I C D E G B A F F H I C D G E B A B A F G E H I C D B3 15L 4 GAL B3 20L 5 3 GAL B3 25L 6 6 GAL B3 30L 8 GAL B3 40L 10 5 GAL B3 60L 15 8 GAL B3...

Страница 15: ...64 F 304 318 11 31 32 12 1 2 G 320 12 19 32 H 87 3 27 64 I 259 10 13 64 30L 7 9 gal 40L 10 5 gal A 495 19 31 64 623 24 13 32 B 366 14 13 32 C 158 6 7 32 D 75 2 61 64 E 366 14 13 32 F 304 318 11 31 32...

Страница 16: ...p A Via Piangipane 120 A 48124 Piangipane RAVENNA ITALY Tel 39 0544 415061 Fax 39 0544 415047 www quickitaly com quick quickitaly com B3Series WATER HEATER SERIES B3 REV 001A B3 15 15 12V B3 20 20 12V...

Отзывы: