Testing an Extension Lead
1.
Plug the extension lead into the socket on top of the tester
2.
Plug the IEC end of the short IEC lead into the IEC socket on the
front of the microPAT
3.
Plug the 13A plug end of the short IEC lead into the first socket of
the extension lead
4.
Press the Cable button, or Surge Cable button if the extension lead
is surge protected
The Cable or Surge Cable test button will flash amber while the test is
underway.
When the test is finished, either the green PASS indicator will light up, or
the appropriate red FAIL indicators will light up. The test button will also be
green or red.
The test must be repeated for ALL sockets on the extension lead.
If the extension lead has an earth connection, but the reading is high
because the lead is exceptionally long, the green PASS indicator will light
up, however the Earth Continuity FAIL indicator will flash amber. In this
case the extension lead should only be used in exceptional circumstances
where the risks are clearly understood.