12

of the laser is not enough.

3. The C/N index of system link

signal is too low.

the optical transmitter and adjust to
the device required input range.
(72--88dBμV). When the input
channel number less than 15, set to
the MGC control mode.

3. Use a spectrum analyzer to check

the system link C/N and make
appropriate adjustments. Make
sure the system link signal C/N

51dB.

After initial startup, the image of
several optical contact points
randomly appear obvious noises
or bright trace.

The optical contact point has open
circuit signal interference or strong
interference signal intrusions.

1. Check if there is a strong

interference signal source; change
the optical contact point location if
possible to avoid the influence of
strong interference signal sources.

2. Check the cable lines before the

optical contact point, the shielding
net or the RF connector shielding
effect is not good.

3. Close the equipment enclosure

tightly to ensure the shielding
effect; if possible add shielding
cover to the optical contact point
and reliable grounding.

After initial startup, at optical
contact points, the image of
several channels have obvious
noises.

The C/N indexes of these channels
are too low.

Check the C/N of these channels signal
and make appropriate adjustments.

After initial startup, the image of
several optical contact points
appear one or two horizontal
bright traces.

Power supply AC ripple
interference because of the bad
earth of equipment or power
supply.

Check grounding situation of the
equipment; make sure that every
equipment in the line has been reliably
grounding and the grounding resistance
is

4Ω.

After initial startup, the received
optical power of the optical
contact point is unstable and has
large continuous change. The RF
output signal is unstable too. But
the detected optical output
power of the optical transmitter
is normal.

The fiber connector types do not
match, maybe the APC type
connect to PC type, make the
optical signal cannot normal
transmission. The active fiber
connector or adapter may be
contaminated seriously or the
adapter has been broken.

1. Check the fiber connector type;

adopt the APC type fiber connector
to ensure the normal transmission
of optical signal.

2. Clean the contaminated active fiber

connector or adapter. Specific
operation methods see “The clean
and maintenance method of optical
fiber connector”.

3. Replace the damaged adapter.

Optical Transmitter

 User Manual

 

 L-RF-32mW-TX

www.questtel.com

[email protected]

Содержание L-RF-32mW-TX

Страница 1: ...User Manual CATV 32 mW RF Optical Transmitter 47 750 862 1003 MHz L RF 32mW TX www questtel com sales questtel com...

Страница 2: ...hile the optical transmitter is working there is an invisible laser beam from the optical output adapter on the front panel Avoiding permanent harm to the body and eye the optical output should not ai...

Страница 3: ...ccording to the RF input signal level and the number of channels 15 84 channels make the CSO CTB and C N index always at the optimal value to ensure the overall performance Advanced multi frequency RF...

Страница 4: ...alog TV channel signal at 750MHz frequency range under the specified link loss When the optical input power of optical receiver is 1dBm measure the C CTB C CSO and C N 4 2 Technique Parameters Table I...

Страница 5: ...gradation table Optical power Optical link loss dB 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4mW 53 8 52 8 51 8 51 50 1 49 2 48 2 6mW 53 0 52 0 51 0 50 1 49 1 48 1 8mW 52 8 51 9 51 0 50 1 49 2 48 2 10mW...

Страница 6: ...eans the RF input signal is warned green light means RF input signal is normal 5 160 32 dot matrix LCD screen used to display all the parameters of the machine 6 Display the exit or cancel key of the...

Страница 7: ...output port of the device The connector type is FC APC There is an invisible laser beam from this port while working normal So the port should not be aligned to human body or naked eye to avoid accid...

Страница 8: ...ress Enter key into the menu index 1 Parameter menu 2 Set parameters 3 Alarm menu 5 Sub menu of parameters Press Enter key into the menu Content Meaning Optical output power of the laser at present Bi...

Страница 9: ...e Switching power supply output 5V supply voltage Switching power supply output 5V supply voltage Switching power supply output 24V supply voltage Serial number Internal temperature at present IP addr...

Страница 10: ...GC or MGC Set the attenuation of MGC Set the offset of AGC start control level Set system transmission channels number This parameter is used to correct the accuracy of displayed laser RF signal level...

Страница 11: ...t to the rack and reliably grounding The grounding resistance must be 4 3 Use the digital multimeter to check the supply voltage make sure the supply voltage comply with the requirements and the switc...

Страница 12: ...tlike curve or large particles highlights 1 The received optical power of the optical contact point is too high the output level of the optical receiver module is too high and intermodulation index of...

Страница 13: ...s noises The C N indexes of these channels are too low Check the C N of these channels signal and make appropriate adjustments After initial startup the image of several optical contact points appear...

Страница 14: ...ptical power is on the low side after clean the adapter may be polluted clean it Note Adapter should be carefully operated so as to avoid hurting inside fiber 6 Use compressed air or degrease alcohol...

Страница 15: ...ck 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never...

Отзывы: