7. Common Failure Analysis and Troubleshooting

Failure phenomenon

Failure cause

Solution

Power on, the front panel
display screen and power
indicator are both off.

Switching power supply couldn't
start; equipment; internal DC
power supply is not working.

Check if the power supply is normal
(should be AC: 110V-250V). If the
supply voltage is normal, it could be a
failure of switching power supply
module. Please contact the dealer or
our company.

Power on; the display screen is
off, only the power indicator is
on.

The internal microprocessor is not
working.

Please contact the dealer or our
company.

Power on; the optical output
power displayed on the front
panel display screen and laser
status indicator are both normal,
but the actual measured optical
output power is low.

1. The poor quality of the test

jumper.

2. The active fiber connector or

adapter may be contaminated.

3. The ceramic tube in the

adapter may have been
broken.

1. Replace with good quality test

jumper.

2. Clean the contaminated active fiber

connector or adapter. Specific
operation methods see “The clean
and maintenance method of optical
fiber connector”.

3. Replace the damaged adapter.

After initial startup, the image of
the optical contact point has
obvious netlike curve or large
particles highlights.

1. The received optical power of

the optical contact point is too
high; the output level of the
optical receiver module is too
high and intermodulation
index of RF signal
deteriorates.

2. The RF signal input of the

optical transmitter is too high;
beyond the device AGC
control range, results in
deterioration of the
intermodulation index.

3. The intermodulation index of

RF signal input of the optical
transmitter itself is poor.

1. Check the received optical power

of the optical contact point and
make appropriate adjustments.

2. Check the input level of the optical

transmitter RF signal, and adjust to
the device required input range.
(RF signal input level should be
72--88dBμV).

3. Check the intermodulation index of

the RF signal input of the optical
transmitter and make appropriate
adjustments.

After initial startup, the image of
the optical contact point has
obvious noises.

1. The received optical power of

the optical contact point is not
high enough, results in
decrease of C/N.

2. The RF signal level input of

the optical transmitter is too
low; make modulation degree

1. Recover received optical power of

the optical contact point by
cleaning the active fiber connector
or. Specific operation methods see
“Clean and maintenance methods
of optical fiber connector”.

2. Check the RF signal level input of

Optical Transmitter

 User Manual

 

 L-RF-32mW-TX

www.questtel.com

[email protected]

Содержание L-RF-32mW-TX

Страница 1: ...User Manual CATV 32 mW RF Optical Transmitter 47 750 862 1003 MHz L RF 32mW TX www questtel com sales questtel com...

Страница 2: ...hile the optical transmitter is working there is an invisible laser beam from the optical output adapter on the front panel Avoiding permanent harm to the body and eye the optical output should not ai...

Страница 3: ...ccording to the RF input signal level and the number of channels 15 84 channels make the CSO CTB and C N index always at the optimal value to ensure the overall performance Advanced multi frequency RF...

Страница 4: ...alog TV channel signal at 750MHz frequency range under the specified link loss When the optical input power of optical receiver is 1dBm measure the C CTB C CSO and C N 4 2 Technique Parameters Table I...

Страница 5: ...gradation table Optical power Optical link loss dB 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 4mW 53 8 52 8 51 8 51 50 1 49 2 48 2 6mW 53 0 52 0 51 0 50 1 49 1 48 1 8mW 52 8 51 9 51 0 50 1 49 2 48 2 10mW...

Страница 6: ...eans the RF input signal is warned green light means RF input signal is normal 5 160 32 dot matrix LCD screen used to display all the parameters of the machine 6 Display the exit or cancel key of the...

Страница 7: ...output port of the device The connector type is FC APC There is an invisible laser beam from this port while working normal So the port should not be aligned to human body or naked eye to avoid accid...

Страница 8: ...ress Enter key into the menu index 1 Parameter menu 2 Set parameters 3 Alarm menu 5 Sub menu of parameters Press Enter key into the menu Content Meaning Optical output power of the laser at present Bi...

Страница 9: ...e Switching power supply output 5V supply voltage Switching power supply output 5V supply voltage Switching power supply output 24V supply voltage Serial number Internal temperature at present IP addr...

Страница 10: ...GC or MGC Set the attenuation of MGC Set the offset of AGC start control level Set system transmission channels number This parameter is used to correct the accuracy of displayed laser RF signal level...

Страница 11: ...t to the rack and reliably grounding The grounding resistance must be 4 3 Use the digital multimeter to check the supply voltage make sure the supply voltage comply with the requirements and the switc...

Страница 12: ...tlike curve or large particles highlights 1 The received optical power of the optical contact point is too high the output level of the optical receiver module is too high and intermodulation index of...

Страница 13: ...s noises The C N indexes of these channels are too low Check the C N of these channels signal and make appropriate adjustments After initial startup the image of several optical contact points appear...

Страница 14: ...ptical power is on the low side after clean the adapter may be polluted clean it Note Adapter should be carefully operated so as to avoid hurting inside fiber 6 Use compressed air or degrease alcohol...

Страница 15: ...ck 7 Object and Liquid Entry Never push objects of any kind into this product through openings as they may touch dangerous voltage points or short out parts resulting in a fire or electric shock Never...

Отзывы: