SERVICE PARTS LIST

Item  Part No 

 Description

1   

4029507 

 CONTROL, HIGH PRESSURE

2   

4042474 

 CONTACTOR, 3-POLE 

(QTY 2)

 

3   

4042114 

 TRANSFORMER

4   

4036559 

 CIRCUIT BREAKER

5   

4039667 

 THERMISTOR 

w

/

clamp

 

(QTY 2) (NOT SHOWN)

6   

4042979 

 CPRSR

7   

4037702 

 FILTER, DRIER

8   

4037703-04   COIL, EVAP

9   

4037699 

 THERMISTOR 

bulb

 

(QTY 2) (NOT SHOWN)

  

10  

4039605-02    COIL,  MICRO 

(QTY 4)

  

11   

4039661 

 EEV

12  

4042479 

 FAN,MOTORIZED  IMPELLER

13  

4038135 

 HANDLE,  POCKET 

(QTY 4)

 

1 4 

4038136 

  BEZEL,  HANDLE 

(QTY 4)

 Item  Part No 

 Description 

15  

4042586 

 WIRE  HARNESS 

(NOT SHOWN)

 16 

4038079 

 LUG,  GROUND

17  

4038219 

 FOOT, RUBBER, 1.25” DIA 

(QTY 4)

18  

4038225-01   BRACKET, FOOT, RIGHT

19  

4038226-01   BRACKET, FOOT, LEFT

 20 

4042475 

  BLOCK,  WIRING

21  

4042596 

 PLC

22 

4038233 

 FILTER - 18 

x

 20 

x

 2 

(QTY 2)

23 4039862   

PRESSURE TRANSDUCER

24 

4042477 

 CPRSR WIRE HARNESS 

(NOT SHOWN)

25 

4041558  

 PLC DISPLAY

26 

4041559 

 DISPLAY CABLE ASSEMBLY 

(NOT SHOWN)

27 

4039875 

 PCB

28 

4034716-08   THERMISTOR 

probe

Part No 

 Qty 

Description 

 

4028531 

DEH 3000R Control, Remote

4022220 

Kit, Pump

4038642 

Kit, Intake Duct

Part No 

 Qty 

Description 

 

4039868 

Kit, Exhaust Duct

4038644 

Drain Trap Kit

OPTIONAL PARTS LIST

Содержание 746

Страница 1: ...astor com patents T S 2005 02 24 R E V D Quieter Operation Patented M CoRR Technology Industry Leading Efficiency Superior MERV 13 Air Filtration Integrated Lift and Hang Points Auto Restart After Pow...

Страница 2: ...ons 6 5 1 Humidity Control 6 5 2 24VAC Wiring 6 5 2A Deh 3000R 7 5 2B Honeywell Remote Humidistat 7 5 2C Daisy Chain 7 Maintenance 8 6 1 Standard Air Filter 8 7 Service 8 7 1 Warranty 8 7 2 Technical...

Страница 3: ...an outlet that is a GROUND FAULT INTERRUPT protected circuit DO NOT use the device as a bench or table DO NOT place the device directly on structural members Provide vibration isolation in order to m...

Страница 4: ...se 60 Hz CURRENT DRAW 6 5A RATED CURRENT DRAW 104 F 36 7 5A MCA 10A MOP 15A RECOMMENDED BREAKER SIZE 10A ENERGY FACTOR L KWH 3 45 OPERATING TEMP 56 F Min 95 F Max WATER REMOVAL PINTS DAY EFFICIENCY PI...

Страница 5: ...wired directly to the electrical service The current draw under normal operating conditions is listed in section 3 Information required for proper electrical service installation and overcurrent prote...

Страница 6: ...mation on the kit FOLLOW DIAGRAM Level unit within 2 4 4 HANGING DIAGRAM WARNING Hanging installation must meet all state and local codes WARNING Installation should be done by a qualified agency in a...

Страница 7: ...Control DEH 3000R Honeywell Humidistat Any 24V signal to dehumidify CAUTION Low Voltage Hazard Can cause equipment damage Disconnect power before beginning installation 5 2 24VAC WIRING The terminal b...

Страница 8: ...MOTE HUMIDISTAT WIRING DIAGRAM QUEST DEH 3 WIRING Red Black C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT C FAN R DHUM COMPRESSOR AND FAN FLOAT FLOAT 24VAC COMP FAN QUEST DEH 3000R CONTROLER C FAN R DHU...

Страница 9: ...property damage Only qualified service personnel should service this unit 7 1 WARRANTY A warranty certificate has been enclosed with this unit read it before any repair is initiated If a warranty repa...

Страница 10: ...sure to use appropriate size duct branches to maintain proper feed throughout the ducting system System control should be placed remotely from the dehumidifier in a central location Intake and exhaust...

Страница 11: ...a menu selection screen moves cursor up On an editable value increases the value Press and hold to change the value faster If cursor is in upper left corner of a screen moves to previous screen Enter...

Страница 12: ...rom any screen press the Prg Bullseye key This will prompt for a password 2 Press Enter four times to access the menu Then press Up Down keys until Settings is highlighted 3 Press Enter to enter Setti...

Страница 13: ...rm key If there are active alarms this will display a screen like this 2 Press Up Down to cycle through all active alarms The alarms are arranged in order of their alarm code lowest to highest One scr...

Страница 14: ...een except for a few differences The Alarm Log screen does not display the current operating mode The Alarm Log screen shows both when the alarm was first triggered Event Start and when the fault cond...

Страница 15: ...HANDLE POCKET QTY 4 14 4038136 BEZEL HANDLE QTY 4 Item Part No Description 15 4042586 WIRE HARNESS NOT SHOWN 16 4038079 LUG GROUND 17 4038219 FOOT RUBBER 1 25 DIA QTY 4 18 4038225 01 BRACKET FOOT RIGH...

Страница 16: ...15 QUEST 746 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS QUESTCLIMATE COM 877 420 1330...

Страница 17: ...16 QUEST 746 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS QUESTCLIMATE COM 877 420 1330 WIRING DIAGRAM OF THE QUEST 746 DEHUMIDIFIER 4042587 REV B...

Страница 18: ...17 QUEST 746 INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS QUESTCLIMATE COM 877 420 1330 SEE BACK FOR WARRANTY AND REGISTRATION...

Страница 19: ...sion freezing tampering modification unauthorized or improper repair or installation accident acts of nature or any other cause beyond Therma Stor LLC s reasonable control LIMITATIONS AND EXCLUSIONS I...

Отзывы: