QUEST 746
INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS
QUESTCLIMATE.COM
(877) 420-1330
4.3 CONDENSATE WATER REMOVAL
Condensate drains by gravity via the drain port. Use 3/4” male NPT PVC pipe. An optional
condensate pump kit may be installed if a lift is required to dispose of the condensate. Optional parts
list for information on the kit.
FOLLOW DIAGRAM:
Level unit within 2°
4.4 HANGING DIAGRAM
WARNING!
Hanging installation must meet all state and local codes.
WARNING!
Installation should be done by a qualified agency in accor-
dance with these instructions. The qualified service agency installing this high
efficiency refrigeration system is responsible for the installation.
3/4” drain port
28.95
"
27.25
"
3/8” threaded rod
Intake Air
Treated Air
3/8” Jam Nuts
5.56”
PARTS NEEDED:
4 pieces 3/8” threaded rod (not included)
4 - 3/8” threaded jam nuts (not included