11
5. Installaon Instrucons – Mounng/ Removal
To Remove the Alarm
Once the alarm has entered end of life or error mode it is necessary to turn it off. This will silence
the alarm and safely discharge the remaining baery capacity.
1. Remove the bracket/back cover from the unit by sliding a screwdriver between the unit and the cover
at the recess in the centre of the unit. This allows access to the back of the unit.
2. Once the back of the unit is visible, locate the slot on the lower le hand side. The switch to
turn the alarm off is located in this slot.
3. Insert a small flat blade screwdriver in the slot and use it to slide the switch
towards the boom of the alarm. Be sure to insert the screwdriver straight in
and not at an angle where the switch might be missed.
The unit may make some brief noises but should be silent and
not connue to beep aer one (1) minute.