background image

 

e

-

ASK

 

e

lectronic

 

A

ccess

 

S

ecurity

 

K

eyless-entry

 

 
 

e

e

-

-

FOB

FOB

 

 

RF Keyless

RF Keyless

-

-

entry

entry

 

 

System Instructions

System Instructions

 

 

(UM02 ~ 19571-02)

 

 

Содержание e-Ask e-FOB

Страница 1: ...e ASK electronic Access Security Keyless entry e e FOB FOB RF Keyless RF Keyless entry entry System Instructions System Instructions UM02 19571 02...

Страница 2: ...ision 5 DIP Switch 5 Staggered Lock Unlock 5 Additional System Features 5 Light Activation 5 2nd Unlock Output 5 Panic Mode 5 Vehicle Alarm 6 Valet Mode 6 In Vehicle Valet Activation 6 Remote Valet Ac...

Страница 3: ...on Panic mode Auxiliary functions based upon configuration see page 4 The e FOB system includes Receiver 2 FOB transmitters 14 pin wire harness 10 pin wire harness 4 pin wire harness Smart LED Push bu...

Страница 4: ...ment on page 4 Lock button Horn button button Unlock button 2 Button Function Lock Locks all entry doors and arms security system Unlock Unlocks entry doors and disarms security system Also activates...

Страница 5: ...proper e FOB transmitter and receiver reception Notes If you place the system in learn mode and teach nothing the system will exit in 10 seconds If the 4 transmitter limit is exceeded the system erase...

Страница 6: ...itch change is recognized after the Lock button is pressed Functional assignments are described below DIP Switch 1 Sustained Output DIP switch 1 ON output of lower left button is controlled by DIP swi...

Страница 7: ...ice on an unlock command DIP Switch 5 Staggered Lock Unlock DIP switch 5 ON the staggered locking output occurs with lock actuation DIP switch 5 OFF the staggered lock output is staggered to the lock...

Страница 8: ...door must have door ajar switches 2 Turn the ignition to the ON position with your key 3 Press the button lower right Note Repeat activation to toggle valet mode off In the valet mode the doors lock a...

Страница 9: ...BYPASS THE IGNITION OR FUEL PUMP In case of an emergency the starter kill feature can be bypassed with the emergency override Emergency Override To disarm the alarm in case of FOB transmitter loss 1 T...

Страница 10: ...Problem Description Possible Solution Button press does not provide correct operation Verify power to the RF receiver Replace FOB transmitter battery Re teach the FOB transmitter to the receiver No o...

Страница 11: ...rior location that does not shield RF signals You may need to try multiple locations to optimize reception The antennae must be left fully extended and exposed Minimize shielding from metal enclosures...

Страница 12: ...UND SOLID CONNECTION IS A MUST 6 SIREN OUTPUT UP TO 2 A CAPACITY BROWN SHORT PROTECTED 7 CONNECT TO A STRONG POWER SOURCE USE A FUSE RED AT THE CONNECTION POINT 8 BLUE WHITE UNLOCK INPUT N C RELAY 87...

Страница 13: ...N UNASSIGNED INPUT 6 WHITE BLUE STAGGERED LOCKING 7 BLUE SECONDARY TRIGGER INPUT TRUNK HOOD 8 GREEN DOOR TRIGGER INPUT 9 PURPLE DOOR TRIGGER INPUT 10 WIRE COLORS 4 PIN HARNESS WHITE RED UNLOCK INPUT F...

Страница 14: ...IV Wiring Connections for Basic System Functions...

Страница 15: ...Notes...

Страница 16: ...UM02 19571 02 01 06 8...