background image

DIP Switch #3: Automatic Lock/Unlock 



DIP switch #3 ON: the auto-locking feature is activated. All 
doors are locked 5-seconds after engine start. Doors unlock 
when the engine is turned off. THIS FEATURE IS CANCELED 
AUTOMATICALLY if the door is open or opened when the    
engine is started. This protects against accidental locking of 
keys in the vehicle.  



DIP switch #3 OFF: Automatic lock/unlock feature is disabled.  

 

DIP Switch #4: Parking Light Supervision 



DIP switch #4 ON: the parking and headlights are actuated with 
the dome lights. Lights flash with a lock command. Lights  

 

remain illuminated for 30 seconds with an unlock command. 
Locking the doors or starting the car deactivates the lights     
immediately.  



DIP switch #4 OFF: the parking and headlights flash once on a 
lock command and twice on an unlock command. 

 

DIP Switch #5: Staggered Lock/Unlock 



DIP switch #5 ON: the staggered locking output occurs with 
lock actuation.  



DIP switch #5 OFF: the staggered lock output is staggered to 
the lock actuation to decrease peak current draw.  

 

Additional System Features  

 

Light Activation 

When the Lock button is pressed, the parking and headlights flash. With 
an unlock instruction; the dome light stays illuminated for 30 seconds. 
The parking and headlight actuation is controlled by DIP switch #4. 
 

2nd Unlock Output (optional: extra installation  
required) 

Press and hold the Unlock button until activation (2 seconds).  
A sustained output is available through the white/brown wire on the  
10-pin harness. See appendix page III for output definition.  
 

Panic Mode 

Pressing and holding the Horn button (lower left) for 2 seconds  
activates panic mode. During panic mode, horn/siren is continuously 
activated and headlights flash for 1 minute. Pressing the Unlock button 
deactivates panic mode.  

Содержание e-Ask e-FOB

Страница 1: ...e ASK electronic Access Security Keyless entry e e FOB FOB RF Keyless RF Keyless entry entry System Instructions System Instructions UM02 19571 02...

Страница 2: ...ision 5 DIP Switch 5 Staggered Lock Unlock 5 Additional System Features 5 Light Activation 5 2nd Unlock Output 5 Panic Mode 5 Vehicle Alarm 6 Valet Mode 6 In Vehicle Valet Activation 6 Remote Valet Ac...

Страница 3: ...on Panic mode Auxiliary functions based upon configuration see page 4 The e FOB system includes Receiver 2 FOB transmitters 14 pin wire harness 10 pin wire harness 4 pin wire harness Smart LED Push bu...

Страница 4: ...ment on page 4 Lock button Horn button button Unlock button 2 Button Function Lock Locks all entry doors and arms security system Unlock Unlocks entry doors and disarms security system Also activates...

Страница 5: ...proper e FOB transmitter and receiver reception Notes If you place the system in learn mode and teach nothing the system will exit in 10 seconds If the 4 transmitter limit is exceeded the system erase...

Страница 6: ...itch change is recognized after the Lock button is pressed Functional assignments are described below DIP Switch 1 Sustained Output DIP switch 1 ON output of lower left button is controlled by DIP swi...

Страница 7: ...ice on an unlock command DIP Switch 5 Staggered Lock Unlock DIP switch 5 ON the staggered locking output occurs with lock actuation DIP switch 5 OFF the staggered lock output is staggered to the lock...

Страница 8: ...door must have door ajar switches 2 Turn the ignition to the ON position with your key 3 Press the button lower right Note Repeat activation to toggle valet mode off In the valet mode the doors lock a...

Страница 9: ...BYPASS THE IGNITION OR FUEL PUMP In case of an emergency the starter kill feature can be bypassed with the emergency override Emergency Override To disarm the alarm in case of FOB transmitter loss 1 T...

Страница 10: ...Problem Description Possible Solution Button press does not provide correct operation Verify power to the RF receiver Replace FOB transmitter battery Re teach the FOB transmitter to the receiver No o...

Страница 11: ...rior location that does not shield RF signals You may need to try multiple locations to optimize reception The antennae must be left fully extended and exposed Minimize shielding from metal enclosures...

Страница 12: ...UND SOLID CONNECTION IS A MUST 6 SIREN OUTPUT UP TO 2 A CAPACITY BROWN SHORT PROTECTED 7 CONNECT TO A STRONG POWER SOURCE USE A FUSE RED AT THE CONNECTION POINT 8 BLUE WHITE UNLOCK INPUT N C RELAY 87...

Страница 13: ...N UNASSIGNED INPUT 6 WHITE BLUE STAGGERED LOCKING 7 BLUE SECONDARY TRIGGER INPUT TRUNK HOOD 8 GREEN DOOR TRIGGER INPUT 9 PURPLE DOOR TRIGGER INPUT 10 WIRE COLORS 4 PIN HARNESS WHITE RED UNLOCK INPUT F...

Страница 14: ...IV Wiring Connections for Basic System Functions...

Страница 15: ...Notes...

Страница 16: ...UM02 19571 02 01 06 8...

Отзывы: