Parameter
Description
Conditions
Min. Typ. Max. Unit
VBAT_RF
the minimum and maximum values.
USB_VBUS
USB connection
detection
3.0
5.0
5.25
V
5.3.
Operation and Storage Temperatures
Table 33: Operation and Storage Temperatures
Parameter
Min.
Typ.
Max.
Unit
Operation Temperature Range
1)
-35
+25
+75
º
C
Extended Temperature Range
2)
-40
+85
º
C
eCall Temperature Range
3)
-40
+90
º
C
Storage Temperature Range
-40
+95
º
C
1.
1)
Within operation temperature range, the module is 3GPP compliant, and emergency call can be dialed out
with a maximum power and data rate.
2.
2)
Within extended temperature range, the module remains fully functional and retains the ability to establish
and maintain functions such as voice, SMS, data transmission and emergency call, without any unrecoverable
malfunction. Radio spectrum and radio network will not be influenced, while one or more specifications, such
as P
out
, may undergo a reduction in value, exceeding the specified tolerances of 3GPP. When the temperature
returns to the normal operating temperature level, the module will meet 3GPP specifications again.
3.
3)
Within eCall temperature range, the emergency call function must be functional until the module is broken.
When the ambient temperature is between 75 °C and 90 °C and the module temperature has reached the
threshold value, the module will trigger protective measures (such as reduce power, decrease throughput and
unregister the device) to ensure the full function of emergency call.
5.4.
Current Consumption
NOTES