Table 51: EC200U-AU Conducted RF Receiving Sensitivity
Frequency
Receiving Sensitivity (Typ.)
3GPP
Primary
GSM850
TBD
-102.0 dBm
EGSM900
TBD
-102.0 dBm
DCS1800
TBD
-102.0 dBm
PCS1900
TBD
-102.0 dBm
LTE-FDD B1 (10 MHz)
TBD
-96.3 dBm
LTE-FDD B2 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B3 (10 MHz)
TBD
-93.3 dBm
LTE-FDD B4 (10 MHz)
TBD
-96.3 dBm
LTE-FDD B5 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B7 (10 MHz)
TBD
-94.3 dBm
LTE-FDD B8 (10 MHz)
TBD
-93.3 dBm
LTE-FDD B28 (10 MHz)
TBD
-94.8 dBm
LTE-FDD B66 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B38 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B40 (10 MHz)
TBD
-96.3 dBm
LTE-TDD B41 (10 MHz)
TBD
-94.3 dBm
5.7. ESD
If the static electricity generated by various ways discharges to the module, the module maybe damaged
to a certain extent. Thus, please take proper ESD countermeasures and handling methods. For example,
wearing anti-static gloves during the development, production, assembly and testing of the module;
adding ESD protective components to the ESD sensitive interfaces and points in the product design.
The following table shows the module electrostatics discharge characteristics.