To make the IR Relay (BICOM) responsive to the digital input, in addition to the setting
of the configuration parameter 7, parameter 100 must also be set to value 1 or 2.
Parameter no. 40
–
Reporting on power change
This parameter is valid for Active Power Total, Active Power Phase1, Active Power Phase2 and
Active Power Phase3.
Set value means percentage from 0-100 = 0% - 100%
•
Available configuration parameters (data type is 1 Byte DEC)
•
Default value 50
•
0
–
reporting disabled
•
1-100 = 1% - 100% reporting enabled. Power report is send only when actual power
in Watts (in real time changes for more than set percentage comparing to previous
Active Power, step is 1%.
NOTE: if power change is less than 5 W, the report is not send (pushed).
NOTE: Device is measuring also some disturbances even if on the output is no load. To avoid
disturbances:
•
If measured Active Power (W) is below e.g. 5W-> the reported value in this case is
0W