9. Electrical Diagram 3 X 230VAC
Notes for diagram:
L1I, L2I, L3I
Live input
NI
Neutral input
L1O,L2O, L3O
Live output
No
Neutral output
16
Input for IR external relay/Ext. relay
15
Output for External relay (max. 3W)
S
Service button (used to add or remove device from the Z-Wave network)
LED1
Device status. For detailed information please check the chapter
“
LED
SIGNALIZATION FOR INCLUSION/EXCLUSION
”
LED2
External relay status. For detailed information please check chapter LED
SIGNALIZATION FOR INCLUSION/EXCLUSION
IR
Output for IR external relay (BICOM)
1000imp/Wh
Red - Pulse rate (On
–
no load indication)