The Qubino 3-Phase Smart Meter is an extremely versatile and powerful Z-Wave device for
measuring energy in a three-phase electrical power network of up to 3 x 65A.
Страница 1: ...R MANUAL EN QUBINO 3 PHASE SMART METER The Qubino 3 Phase Smart Meter is an extremely versatile and powerful Z Wave device for measuring energy in a three phase electrical power network of up to 3 x 6...
Страница 2: ...Switches 19 6 Compatibility with Z Wave Gateways hubs 20 7 Installation 21 8 Device Information and Support 31 9 Electrical Diagram 3 X 230VAC 32 10 Adding the device to a Z Wave network Inclusion 37...
Страница 3: ...additional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We...
Страница 4: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...
Страница 5: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...
Страница 6: ...NHXD6 50 60 Hz 868 4 MHz ZMNHXD7 50 60 Hz 919 8 MHz ZMNHXD8 50 60 Hz 865 2 MHz ZMNHXD9 50 60 Hz 922 5 MHz ZMNHXDA 50 60 Hz 919 7 921 7 923 7 MHz ZMNHXDB 50 60 Hz 868 1 MHz ZMNHXDC 50 60 Hz 868 1 MHz Z...
Страница 7: ...and utility applications The device measures energy directly in 4 wire networks according to the principle of fast sampling of voltage and current signals It is designed to be mounted on DIN rail The...
Страница 8: ...umulated kVAh Energy Reactive power accumulated kvarh Optional 3 Phase Smart Meter supported functions Turn ON OFF device 1 Turn ON OFF device 2 Automatically turn ON OFF Z Wave Repeater Auto inclusio...
Страница 9: ...to use Qubino 3 Phase Smart Meter to remotely control devices via your smartphone 2 1 Installation examples for the 3 Phase Smart Meter used for measuring consumption Track power consumption of the ho...
Страница 10: ...devices with additional external contactors IKA BICOM IKA and BICOM are sold separately for more info please see Qubino catalogue Product ordering codes model numbers IKA232 20 230V 030 046 833 000 BI...
Страница 11: ...rol one group of electrical devices for example lights with IKA232 20 230V Track power consumption for each of three electrical devices and control two groups of electrical devices for example 3 phase...
Страница 12: ...consumption For example the heating will automatically turn off after it reaches the set power consumption value This function is independent of other scenes and gateway hub commands Want to control...
Страница 13: ...the only Z Wave 3 Phase Smart Meter where the current is measured by passing through the device not through clamps Measuring the electric consumption with a smart meter using clamps is not as accurate...
Страница 14: ...o the installation is really simple The Qubino 3 Phase Smart Meter is the only 3 phase smart meter worldwide that beside measuring allows you to switch ON OFF two independent electrical circuits by co...
Страница 15: ...Energy Apparent power accumulated kVAh Energy Reactive power accumulated kvarh Qubino guarantees 100 device quality Such high quality can be delivered because every Qubino goes through rigorous quali...
Страница 16: ...serial and part numbers of your device are given automatically every time you open an inquiry with our support team this instantly shares the relevant device information we need to provide the best t...
Страница 17: ...asiest and quickest installations of devices of this kind DIN rail installation Saves and restores the last status after a power failure Supports auto inclusion mode for quick set up Can automatically...
Страница 18: ...EN 18 4 Package Contents 3 Phase Smart Meter Device Installation Manual S2 packaging label...
Страница 19: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...
Страница 20: ...Wave Gateways hubs Please check compatibility with your Z Wave gateway hub before you purchase this device The compatibility table is available online https qubino com products 3 phase smart meter sma...
Страница 21: ...hen the device is turned off voltage may still be present in the device s terminals Note Do not connect the device to loads exceeding the recommended values Connect the device exactly as shown in the...
Страница 22: ...or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some voltage may remain in the...
Страница 23: ...EN 23 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Before Qubino installation...
Страница 24: ...EN 24 After the Qubino installation For measuring the energy of the house...
Страница 25: ...EN 25 For controlling one electrical device with BICOM432 40 WM1 BICOM is sold separately for more info please see Qubino catalogue Product ordering code model number 30 074 038...
Страница 26: ...EN 26 For controlling one electrical device with IKA232 20 230V IKA is sold separately for more info please see Qubino catalogue Product ordering code model number 030 046 833 000...
Страница 27: ...20 230V and one with BICOM432 40 WM1 with additional external contactors IKA BICOM IKA and BICOM are sold separately for more info please see Qubino catalogue Product ordering codes model numbers IKA2...
Страница 28: ...into the Z Wave network Once the device will be mounted access to the DSK code label may be difficult so we suggest rewriting the DSK code or scanning the QR code from the device label before installi...
Страница 29: ...EN 29 Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...
Страница 30: ...EN 30 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino 3 Phase Smart Meter...
Страница 31: ...the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part num...
Страница 32: ...nal relay max 3W S Service button used to add or remove device from the Z Wave network LED1 Device status For detailed information please check the chapter LED SIGNALIZATION FOR INCLUSION EXCLUSION LE...
Страница 33: ...tive power accumulated Export kVAh Energy Apparent power accumulated total kvarh Energy Reactive power accumulated total 3 PHASE SMART METER SUPPORTED UNITS RateType Import kWh kVAh Watt Voltage Amper...
Страница 34: ...te delay for some scales up to 10 minutes Therefore the first real measured values could be reported with the same delay Watchdog To protect the Smart Meter against getting stuck in an undesired state...
Страница 35: ...device One controlled by built in optical IR communication port on the side second controlled by output on terminal 15 IKA and BICOM are sold separately for more info please see Qubino catalogue Prod...
Страница 36: ...he official manual which can be obtained on the following address http qubino com download 1107 IKA232 20 230V IKA232 20 is a bistable switch which can be controlled in contrast to the IR relay using...
Страница 37: ...will be initiated within 5 seconds of connection to the power supply and the device will be automatically added to your network when the device is excluded and re connected to the power supply it auto...
Страница 38: ...vice will be removed from your network but custom configuration parameters will not be erased Wait at least 30 seconds before adding the device back to a network FACTORY RESET 1 Connect the device to...
Страница 39: ...al IR relay is turned OFF LED is 0 5s OFF 0 5s ON IR communication error b External TRIAC relay enabled only LED is ON External IR relay is turned ON LED is OFF External IR relay is turned OFF c Both...
Страница 40: ...upon request Meter Report triggered according to Configuration parameters 40 42 and 43 Switch Binary Report triggered upon change of relay state PG1 Endpoint 1 Group ID Name Allowed nodes Description...
Страница 41: ...to Configuration parameters 40 42 and 43 Switch Binary Report triggered upon change of relay state PG4 Endpoint 4 Group ID Name Allowed nodes Description 1 Lifeline 0 Supports the following command cl...
Страница 42: ...e dec Default value 0 0 disabled 2 IR external relay control mono stable push button 3 IR external relay control bi stable switch 4 External relay control mono stable push button 5 External relay cont...
Страница 43: ...tage from 0 100 0 100 Available configuration parameters data type is 1 Byte DEC Default value 50 0 reporting disabled 1 100 1 100 reporting enabled Power report is send only when actual power in Watt...
Страница 44: ...is reporting only if there was a change of 0 1 in Energy Note In the future will be possible to measure and report also Active Energy on PH1 PH2 and PH3 Parameter no 43 Other Values Reporting on time...
Страница 45: ...then re include the module NOTE 2 If you don t have IR BICOM relay module mounted and you enable IR communication parameter 100 is 1 or 2 there will be no valid IR relay state reported It will be rep...
Страница 46: ...pe is 2 Byte DEC Default value 0 0 no function 10 60000 10W 60000W NOTE Meter is capable of measuring max 3x65A Parameter no 107 External relay IKA power threshold settings maximum power on phase L2 T...
Страница 47: ...s off for a time defined in this parameter After that time the output turns on to check if the overload is still present Available configuration parameters data type is 2 Byte DEC Default value 0 disa...
Страница 48: ...t capacity 1 2 5 mm2 Screws M3 Max torque 1 2 Nm Measuring input Type connection three phase 4u Reference current Iref 5 A Maximum current Imax 65 A Minimum current Imin 0 25 A Starting current 20 mA...
Страница 49: ...IR Input 16 Rated voltage 230 V 20 Input resistance 450 kOhm Safety Indoor Meter yes Degree of pollution 2 Protection class II AC voltage test 4 kV Installation Category 300 Vrms cat III Standard EN 5...
Страница 50: ...nclosure material self extinguish complying UL94 V Indoor Meter yes Degree of pollution 2 AC voltage test 4 kV Standard EN 50470 Distance up to 30 m indoors depending on building materials Weight with...
Страница 51: ...AP COMMAND_CLASS_DEVICE_RESET_LOCALLY S0 S2 COMMAND_CLASS_POWERLEVEL S0 S2 COMMAND_CLASS_VERSION_V2 S0 S2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 S0 S2 COMMAND_CLASS_CONFIGURATION_V1 S0 S2 COMMAND_CLAS...
Страница 52: ...LASS_MULTI_CHANNEL_ASSOCIATION_V3 S0 S2 COMMAND_CLASS_ASSOCIATION_GRP_INFO_V2 S0 S2 COMMAND_CLASS_METER_V4 S0 S2 COMMAND_CLASS_BASIC_V1 S0 S2 not listed in NIF only if one of the relays is enabled COM...
Страница 53: ...PORTED Z Wave COMMAND CLASSES COMMAND_CLASS_ZWAVEPLUS_INFO_V2 COMMAND_CLASS_SECURITY_V1 COMMAND_CLASS_SECURITY_2_V1 COMMAND_CLASS_SUPERVISION_V1 COMMAND_CLASS_ASSOCIATION_V2 S0 S2 COMMAND_CLASS_MULTI_...
Страница 54: ...V4 S0 S2 End Point 5 External Relay DEVICE CLASS GENERIC TYPE GENERIC_TYPE_METER SPECIFIC TYPE SPECIFIC_TYPE_WHOLE_HOME_METER_SIMPLE SUPPORTED Z Wave COMMAND CLASSES COMMAND_CLASS_ZWAVEPLUS_INFO_V2 CO...
Страница 55: ...O_V2 COMMAND_CLASS_SECURITY_V1 COMMAND_CLASS_SECURITY_2_V1 COMMAND_CLASS_SUPERVISION_V1 COMMAND_CLASS_ASSOCIATION_V2 S0 S2 COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION_V3 S0 S2 COMMAND_CLASS_ASSOCIATION_GR...
Страница 56: ...rned OFF Command Class Basic Basic Set Basic Value 0x00 BASIC SET GET on root device is mapped to basic set get of both endpoints COMMAND_CLASS_METER_V1 Default values o Rate Type 1 Import o Scale 0 W...
Страница 57: ...not be lost Do not remove the DSK from the product As a backup measure please use the label in the packaging to record the location where the product has been installed The first five digits of key i...
Страница 58: ...nces as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in...
Страница 59: ...ormation on recycling of this product please contact your local authorities your household waste disposal service or the shop where you purchased the product NOTE User manual is valid for device with...