Parameter no. 76 - Motor operation detection
Define the power consumption threshold at the end positions. Based on this value, the device
will know, that the shutters reached the limit switches.
Values (data type is 1 byte dec):
•
default value 30 = 30W
•
0 - 127 = 1-127 W. The value 0 means that reaching a limit switch will not be detected.
Parameter no. 78 - Forced Shutter calibration
By changing the value of this parameter from 0 to 1, the Shutter enters the calibration mode.
For further information about the calibration process, please see section 9.
Values (data type is 1 byte dec):
•
default value 0
•
1 - Start the calibration process. When the calibration process finishes
(completing the full cycle - up, down and up again), set the value of the
parameter 78 (Forced Shutter calibration) back to 0.