EN
.
40
Parameter no. 45
–
Set value determines at which temperature the device will be turned on even (if the thermostat
was manually set to off).
Values (size is 2 byte dec):
•
default
value 50 (5.0 °C)
•
-125 - 545
•
1000 - Antifreeze functionality disabled
NOTE1
: Antifreeze is activated only in heating mode and it uses hysteresis of ±0.5°C.
NOTE2: If configuration parameter 78 (Scale selection) is set to Celsius, then valid interval is -125
–
125 (-12.5
°C –
12.5
°C, resolution 0.1
°C)
NOTE3: If configuration parameter 78 (Scale selection) is set to Fahrenheit, then valid interval is
95
–
545 (9.5
°F –
54.5
°F, resolution 0.1
°F)
NOTE4: If configuration parameter 78 (Scale selection) is set to Fahrenheit, note that
Fahrenheit values will be converted to Celsius degrees. Due to conversion algorithm please be
advised that configuration value could drift when converting values back and forth.
Parameter no. 59 - Thermostat mode
This parameter determines how the device will operate if it will operate in the heating mode or
in the cooling mode. The range of the hysteresis will remain the same, only operation will change
from heating to cooling and vice versa
Values (size is 1 byte dec):
•
default value 0
•
0 - Heat mode
•
1 - Cool mode
NOTE1: After parameter change, first exclude device (without setting parameters to default
value) and then re include the device!