background image

 EN

.

         

     

 

21 

 

7. Installation 

 

Before  installing  the  device,  please  read  the  following  carefully  and  follow  the  instructions 
exactly: 

 

Danger of electrocution! 

 

Installation of this device requires a great degree of skill and may be performed only by a licensed 
and qualified electrician. Please keep in mind that even when the  device is turned off, voltage 
may still be present in the device

’s terminals.

   

 

Note!

 

Do  not  connect  the  device  to  loads  exceeding  the  recommended  values.  Connect  the  device 
exactly  as  shown  in  the  provided  diagrams.  Improper  wiring  may  be  dangerous  and  result  in 
equipment damage. 

Electrical installation must be protected by directly associated overcurrent protection fuse 10A, 
gG  or  Time  lag  T,  rated  breaking  capacity  1500A  (ESKA  522.727)  must  be  used  according  to 
wiring  diagram  to  achieve  appropriate  overload  protection  of  the  device

The  fuse  must  be 

installed in fuse holder type: Adele contact 503Si/1 DS according to the standard

 IEC60669-2-1. 

 

 

 

 

 

 

 

 

 

 

Содержание FLUSH ON/OFF THERMOSTAT 2

Страница 1: ...O FLUSH ON OFF THERMOSTAT 2 The Qubino Flush On Off Thermostat 2 is ideal for remotely controlling electric or water based underfloor heating systems electric water heaters hot water pumps electric ra...

Страница 2: ...r life easier 13 3 Qubino Flush On Off Thermostat 2 Advantages and Highlights 14 3 1 Advantages 14 3 2 Highlights 16 4 Package Contents 17 5 Technical Terms for Switches 18 6 Compatibility with Z Wave...

Страница 3: ...EN 3 17 Z Wave Security 49 18 Important Disclaimer 50 19 Warning 50 20 Regulations 50...

Страница 4: ...dditional features and parameters for you to play with We love helping people who enjoy creating new ideas for their home and then using their hard work and skill to turn those ideas into reality We a...

Страница 5: ...us reading applications in residential and light commercial environments Mature proven and broadly deployed with over 50 million products sold worldwide Z Wave is by far the world market leader in wir...

Страница 6: ...stalling the device follow the instructions exactly The manufacturer GOAP d o o Nova Gorica shall not be legally responsible for any equipment damage or personal injury caused by incorrect installatio...

Страница 7: ...z 916 0 MHz ZMNKID6 50 60 Hz 868 4 MHz ZMNKID7 50 60 Hz 919 8 MHz ZMNKID8 50 60 Hz 865 2 MHz ZMNKID9 50 60 Hz 922 5 MHz ZMNKIDA 50 60 Hz 919 7 921 7 923 7 MHz ZMNKIDB 50 60 Hz 868 1 MHz ZMNKIDC 50 60...

Страница 8: ...Off Thermostat 2 can measure the power consumption of the connected electrical device and itself has an extremely low power consumption of just 0 4 W The Qubino Flush On Off Thermostat 2 can operate...

Страница 9: ...2 also acts as a Z Wave repeater in order to improve the range and stability of the Z Wave network Flush On Off Thermostat 2 supported functions Turn ON OFF W Measurement kWh Measurement Temperature...

Страница 10: ...your next smart home project Of course there are countless of other options for how to use Qubino Flush On Off Thermostat 2 to remotely control devices via your smartphone 2 1 Installation examples wh...

Страница 11: ...e by controlling circulation pumps for heating radiators Remotely control room temperature by controlling circulation pumps for underfloor heating systems Remotely control room temperature by controll...

Страница 12: ...EN 12 Remotely control room temperature by controlling valves for underfloor heating systems...

Страница 13: ...real time to your smart home app your gateway hub needs to support this feature Know how much power your heating system is using Want to control other devices in your Z Wave network with the Flush On...

Страница 14: ...ffed with lots of electrical cables and where every millimetre counts All this is possible because the Qubino Flush On Off Thermostat 2 is the smallest Z Wave thermostat in the world Qubino guarantees...

Страница 15: ...rial and part numbers of your device are given automatically every time you open an inquiry with our support team this instantly shares the relevant device information we need to provide the best tech...

Страница 16: ...AC or 24 30 VDC Features one of the easiest and quickest installations of devices of this kind fits in even the smallest flush mounting boxes Saves and restores the last status after a power failure D...

Страница 17: ...EN 17 4 Package Contents Flush On Off Thermostat 2 Device Temperature Sensor Installation Manual S2 packaging label...

Страница 18: ...h Switch Bi stable switch Single pole double throw SPDT Two switches controlling the same light circuit of lights Two way switch Three way switch Two way switch Used when you have three or more switch...

Страница 19: ...are installed into the flush mounting box behind the switch You can see some examples of different installation boxes worldwide For more information on how to install your device please refer to the...

Страница 20: ...ateways hubs Please check compatibility with your Z Wave gateway hub before you purchase this device The compatibility table is available online https qubino com products flush onoff thermostat 2 flus...

Страница 21: ...s terminals Note Do not connect the device to loads exceeding the recommended values Connect the device exactly as shown in the provided diagrams Improper wiring may be dangerous and result in equipme...

Страница 22: ...electrical shock and or equipment damage disconnect electrical power at the main fuse or circuit breaker before installation and maintenance Be aware that even if the circuit breaker is off some volt...

Страница 23: ...EN 23 Step 2 Installing the device Connect the device exactly according to the diagrams shown below Qubino installation Installation example for circulation pump for radiators...

Страница 24: ...EN 24 After Qubino installation...

Страница 25: ...possible from metal elements as they may cause signal interference Do not shorten the antenna The device s antenna should be as upright as possible This ensures the device s operational range is maxi...

Страница 26: ...is very dangerous 3 Goap d o o does not take responsibility for any damage or electrical shock due to incorrect sensor assembly 4 The above instructions and description apply to a temperature sensor c...

Страница 27: ...EN 27 Step 3 Turn ON the fuse...

Страница 28: ...EN 28 Step 4 Add the device to your Z Wave network For more details on how to include the device please refer to the Z Wave Inclusion chapter...

Страница 29: ...EN 29 Step 5 The Installation is now complete It s time to make your life more comfortable with the help of the Qubino Flush On Off Thermostat 2...

Страница 30: ...to the device page for more information If you still don t find what you re looking for click on the link to Qubino technical support team They will be able to automatically read the serial and part n...

Страница 31: ...or L and N connection must be used only when connected to 240 VAC S Service button WARNING The service S button must NOT be used when the device is connected to a 110 240V power supply The durability...

Страница 32: ...y level so if you want to use SmartStart you need to include it as S2 Authenticated MANUALLY ADDING THE DEVICE TO A Z WAVE NETWORK MANUAL INCLUSION 1 Enable add remove mode on your Z Wave gateway hub...

Страница 33: ...iguration parameters will not be erased NOTE1 LEARN MODE state allows the device to receive network information from the controller NOTE2 After device is excluded you should wait 30 seconds before per...

Страница 34: ...ggered upon thermostat operating state Idle Heating Cooling 2 Change of output Q 5 Supports the following command Basic set triggered by change of output Q 3 Basic on off too high too low T 5 Supports...

Страница 35: ...supports the following notifications In case the current exceeds 10 A for 6 seconds or more the output is turned off automatically and overload notification is sent Notification Type Notification Even...

Страница 36: ...and on off toggle switch types Values size is 1 byte dec default value 1 0 push button momentary 1 on off toggle switch Parameter no 4 Input 1 contact type This parameter determines how the switch or...

Страница 37: ...rted REGARDLESS of percentage set in this parameter Parameter no 42 Watt Power Consumption Reporting Time Threshold for Q Set value refers to the time interval with which power consumption in Watts is...

Страница 38: ...uration parameter 78 Scale selection is set to Celsius then valid interval is 0 250 0 0 C 25 0 C resolution 0 1 C NOTE2 If configuration parameter 78 Scale selection is set to Fahrenheit then valid in...

Страница 39: ...uration parameter 78 Scale selection is set to Celsius then valid interval is 0 250 0 0 C 25 0 C resolution 0 1 C NOTE2 If configuration parameter 78 Scale selection is set to Fahrenheit then valid in...

Страница 40: ...is 95 545 9 5 F 54 5 F resolution 0 1 F NOTE4 If configuration parameter 78 Scale selection is set to Fahrenheit note that Fahrenheit values will be converted to Celsius degrees Due to conversion alg...

Страница 41: ...Group 3 NOTE2 If configuration parameter 78 Scale selection is set to Celsius then valid interval is 150 1000 15 0 C 100 0 C resolution 0 1 C NOTE3 If configuration parameter 78 Scale selection is set...

Страница 42: ...n parameter 78 Scale selection is set to Fahrenheit then valid interval is 322 2120 32 2 F 212 0 F resolution 0 1 F NOTE4 If configuration parameter 78 Scale selection is set to Fahrenheit note that F...

Страница 43: ...be converted to degrees Celsius Please note that converted values could drift when converting values back and forth Parameter no 110 Temperature Sensor Offset Settings Set value is added to or subtra...

Страница 44: ...nfiguration parameter 78 Scale selection is set to Celsius then valid interval is 0 150 0 C 15 0 C resolution 0 1 C NOTE2 If configuration parameter 78 Scale selection is set to Fahrenheit then valid...

Страница 45: ...65x1 45x0 66 in 4 25x3 77x0 87 in 41 8 mm x 36 8 mm x 15 4 mm 115x96x22 Weight with package 48 g 64 g 1 69oz 2 26oz Electricity consumption 0 4W For installation in boxes 60 mm 2 36 in or 2M depth 60...

Страница 46: ...tings When the temperature is decreasing and reaches point 1 defined by parameter 43 heating device is turned on and remains active until the temperature in the room is not increased to reach point 2...

Страница 47: ...INT_V3 S0 S2 COMMAND_CLASS_THERMOSTAT_OPERATING_STATE_V1 S0 S2 COMMAND_CLASS_NOTIFICATION_V8 S0 S2 COMMAND_CLASS_METER_V4 S0 S2 COMMAND_CLASS_SENSOR_MULTILEVEL_V7 S0 S2 COMMAND_CLASS_ASSOCIATION_V2 S0...

Страница 48: ...odes in the same network will act as repeaters regardless of the vendor in order to increase reliability of the network This device must be used in conjunction with a Security Enabled Z Wave Controlle...

Страница 49: ...nd a copy is inserted in the packaging which must not be lost Do not remove the DSK from the product As a backup measure use the label in the packaging The first five digits of the key are highlighted...

Страница 50: ...Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause und...

Страница 51: ...WEEE Waste electrical and electronic equipment Directive do not dispose of this product as household waste or commercial waste Waste electrical and electronic equipment should be appropriately collec...

Отзывы: