QubicaAMF CenterPunch Скачать руководство пользователя страница 6

CenterPunch Lighting Effects Server Owner's Manual 

 

II 

P/N: 400275000; Rev. F, 03/22 

General installation notes

 

For devices directly connected to the power, it is necessary to check that the electrical capacity of the system 
is  suitable  for  the  maximum  power  requirements  of  the  equipment  (as  indicated  on  the  labels  of  the 
equipment). 

Always open the circuit breaker and disconnect the power plug from the powered units before looking for, 
and clearing, any problem. 

To reduce the risk of fire or electrical shock, do not expose this equipment to moisture. 

This appliance must be positioned such that the mains supply cord connector is accessible after installation. 

Be aware of the voltage being supplied to the equipment (i.e. from 100V to 240V) and that the equipment is 
set for the correct voltage (when applicable). 

Failure to set the equipment for the correct voltage will result in damage to the equipment. 

The electrical safety of the equipment is obtained only when the equipment is connected to an effective 
GROUNDING SYSTEM (in accordance with the existing electrical codes and safety regulations). 

It is necessary to have the power and grounding inspected by a licensed and certified electrician. 

The manufacturer cannot be responsible for possible injury, damages or malfunctioning of the equipment 
due to the absence of or improper grounding of the equipment. 

Temperature and Humidity requirements

 

All QubicaAMF 

ELECTRONIC

 products are specifically designed and engineered to be used inside a bowling 

center environment. 

QubicaAMF 

ELECTRONIC

 equipment has an 

OPERATING

 temperature range of 15° to 35° C (59° to 95° F) and 

an 

OPERATING

 humidity range of 10% to 80%. 

Temperatures and humidity levels outside the listed ranges will negatively affect the operation and lifespan 
of the QubicaAMF 

ELECTRONIC

 equipment. 

QubicaAMF  strongly  suggests  not  to  use  or  store  any  of  the  supplied  electronic  equipment  where  the 
temperature and humidity level cannot stay within the specified ranges. 

Restrictive temperature and humidity requirements are specified by the producer of the lanes that will not 
be listed inside this manual. 

 

Содержание CenterPunch

Страница 1: ...OWNER S MANUAL CENTERPUNCH L I G H T I N G EFFECTS SERVER P N 400275000 REV F 03 22...

Страница 2: ...T UPDATES QubicaAMF reserves the right to revise and or update this manual at any time without obligation to notify any person or entity of such revision The document number revision level and date be...

Страница 3: ...installation 6 1 4 4 Connect the system 7 1 4 4 1 Connection in the case of EDGE String equipped with SYSTEM CONTROLLER ES P N 051 200 90X YY 7 1 4 4 2 Connection in the case of Effect Server X 8 1 4...

Страница 4: ...CenterPunch Lighting Effects Server Owner s Manual P N 400275000 Rev F 03 22 This page intentionally left blank...

Страница 5: ...e 11 Updated How to setup a new light effect combination paragraph on page 12 Added How to create and setup a new light effect combination Conqueror X paragraph on page 12 Updated Use the light effect...

Страница 6: ...y when the equipment is connected to an effective GROUNDING SYSTEM in accordance with the existing electrical codes and safety regulations It is necessary to have the power and grounding inspected by...

Страница 7: ...ct for any reason a standard network device such as a network switch to a port different than the N1 port Connecting a standard network device to a port different than N1 may result in major damages f...

Страница 8: ...ion notes The 4DMX HUB communicates with the front desk via a standard network by the N1 connector located on the upper side of the unit It is connected to the 4HD 5HD CPU that should be mounted on th...

Страница 9: ...D CPU and the 5HD CPU are the core unit for the CenterPunch Lighting Effects Server Their functionality is to control the DMX pit lights They are connected to the 4DMX HUB unit with a single network c...

Страница 10: ...D CPU 3 Part number with bar code P N 288250020 4 List of certifications CE certification 5 Serial number with bar code 6 Electrical specifications 12 VDC Max 33W Ext Pow Plug 1 3 4 Connections On the...

Страница 11: ...port from the rear of the Effect Server X 1 4 2 Prepare your CenterPunch Lighting Effects Server 4DMX HUB unit ONLY Fix the 4HD 5HD CPU to the front side of the 4DMX HUB using the two screws present o...

Страница 12: ...Effects Server Owner s Manual 6 P N 400275000 Rev F 03 22 T 90 255 CenterPunch Lighting Effects Server suggested installation CENTERPUNCH LIGHTING EFFECTS SERVER DMX DIMMER 2 UNITS HOME RUN CABLE MAI...

Страница 13: ...m network cable 1 4 4 1 Connection in the case of EDGE String equipped with SYSTEM CONTROLLER ES P N 051 200 90X YY Connect the N1 NETWORK plug of the Effect Server X to the MAIN Scoring Network switc...

Страница 14: ...etwork switch Connect the D1 DMX COM LINE to the first DMX Dimmer unit of the DECK LIGHTING Connect the D2 DMX COM LINE to the first DMX Dimmer unit of the CAPPING LIGHTING Connect the DMX 120 Ohm ter...

Страница 15: ...lug of the 4DMX HUB to the L1 plug of the 4HD 5HD CPU Connect the N1 NETWORK plug of the 4DMX HUB to the MAIN Scoring Network switch Connect the D1 DMX COM LINE to the first DMX Dimmer unit Connect th...

Страница 16: ...CenterPunch Lighting Effects Server Owner s Manual 10 P N 400275000 Rev F 03 22 This page intentionally left blank...

Страница 17: ...g OR On a Conqueror Pro terminal select SETUP TECHNICAL SETUP CENTERPUNCH DECK LIGHTING 2 Once in the Lane Lighting Server Setup screen check the Enabled option enter the Serial number of the Effect S...

Страница 18: ...hts Lane effects 2 The Lights Lane effects screen will open there are two 2 preset Lane effect combinations selectable by clicking on the drop down menu COMPETITION and OPEN PLAY Otherwise click on Cr...

Страница 19: ...o colors the one specified in From color and the one specified as To color c For some pit light effects the option Velocity will be enabled select between the options Slow to set the effect speed to s...

Страница 20: ...he Conqueror X main menu and select SETUP General Bowling Modes 2 In the Lane lighting area of the Bowling modes screen click on the button 3 A row will appear In this row there are the number of the...

Страница 21: ...area of the Bowling modes screen click on the button 3 A row will appear In this row there are the number of the selected lanes 1 8 means from lane 1 to lane 8 and the name of the assigned Lights com...

Страница 22: ...front desk computer navigate through the Conqueror X main menu and select SETUP Bowling Setup Lane Options OR 1 On a Conqueror Pro terminal select SETUP BOWLING SETUP LANE OPTIONS 2 Click on the Adva...

Страница 23: ...d from the special functions menu it will be performed only once for the specified duration 1 On a front desk computer navigate through the Conqueror X main menu and select HOME Quick Access All Lanes...

Страница 24: ...NES 2 Click on the Special F button 3 Click on the Deck lighting button 4 The CenterPunch deck lighting screen will appear 5 Select the effect from the Effect selection and set the options for the sel...

Страница 25: ...Enter Conqueror X Pro with a user allowed to operate the EFFECT SERVER SETUP 7 On a front desk computer navigate through the Conqueror X main menu and select SETUP Modules Options Setup Upload to Lig...

Страница 26: ...lty CENTERPUNCH LIGHTING EFFECTS SERVER by unplugging the power cord from the 4DMX HUB unit itself 2 Disconnect and remove the 4HD 5HD CPU unit from the 4DMX HUB 3 Disconnect and remove the faulty 4DM...

Страница 27: ...ord length 3m 10 EU PN CABPOWVDESUKO US PN CAB020 DMX 120 Ohm Terminator PN 275002009 DMX Effects Server with 4HD CPU PN 275002018 275002028 with 5HD CPU PN Effect Server X PN 275002032 D i sco nne ct...

Отзывы: