B.E.S. - BOWLER ENTERTAINMENT SYSTEM
Pre-Installation Manual
Copyright 2007 Qubica S.p.A.
March 2007 – rev. 2B
7
A.1.8
TMR - Foul Lights
A dedicated 120V 20A - 240V 10A 50/60 Hz circuit is required for each group of 8 lanes (4
pairs of lanes).
Use no wire smaller than number 12 AWG - 2 mm Ø , rated at 600 Volts.
U.S. only - A three-wire 120V 20A - 240V 10A 50/60 Hz circuit with a continuous, insulated,
third wire (green) equipment ground connecting to the service entrance positive earth ground for
each each group of 8 lanes (4 pairs) is required. A grounded duplex outlet receptacle, such as
Hubbell type, should be located approximately 18” beyond the foul line toward the pinspotters.
This receptacle box is to be mounted to the double division capping support beneath the ball
return cover board. The transformer supplied by Qubica will utilize this receptacle.
A.1.9
TCS Q-DAC unit
A dedicated 120V 20A - 240V 10A 50/60 Hz circuit is required for each group of 60 lanes (30
pairs).
Use no wire smaller than number 12 AWG - 2 mm Ø , rated at 600 Volts.
U.S. only - A three wire, dedicated 120V 20A - 240V 10A 50/60 Hz circuit with a continuous,
insulated third wire (Green) equipment ground connecting to the service entrance positive earth
ground is required.
A single power line must be set up every 60 lanes.
Q-DAC Unit electrical specs: 115-230V, 0.7-0.35A, 50-60Hz.
A.1.10 Q-COM Q-DAC unit
A dedicated 120V 20A - 240V 10A 50/60 Hz circuit is required for each group of 48-96 lanes,
depending on the installation.
Use no wire smaller than number 12 AWG - 2 mm Ø , rated at 600 Volts.
U.S. only - A three wire, dedicated 120V 20A - 240V 10A 50/60 Hz circuit with a continuous,
insulated third wire (Green) equipment ground connecting to the service entrance positive earth
ground is required.
A single power line must be set up every 48-96 lanes, depending on the installation.
Q-DAC Unit electrical specs: 115-230V, 0.7-0.35A, 50-60Hz.
A.1.11 MMS
unit
A dedicated 120V 20A - 240V 10A 50/60 Hz circuit is required for MMS unit.
Use no wire smaller than number 12 AWG - 2 mm Ø , rated at 600 Volts.
U.S. only - A three wire, dedicated 120V 20A - 240V 10A 50/60 Hz circuit with a continuous,
insulated third wire (Green) equipment ground connecting to the service entrance positive earth
ground is required.
MMS Unit electrical specs: 100-240V, 1.6-0.6A, 50-60Hz.
A.1.12 Action
Replay
The Action Replay unit can be connected to the RDB line.