![Quattroflow QF5K Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/quattroflow/qf5k/qf5k_operating-manual_3574028008.webp)
Description
8
3.3
Technical data
The technical data refer to a standard version of the pump. Special pump versions (e.g. special connectors)
may have different data. See the extended documentation.
Description
Unit
QF5K
QF5K-HT
QF5KQCon
QF5KCD
Flow rate eccentric shaft 5°
max.
lph
6000
5000
min.
lph
200
50
Pressure according to temperature of fluid
< 40°C
bar
6 (4 continuous)
> 40°C
bar
4
Maximum temperatures
Pumped fluid
°C
80 (short-term)
CIP
°C
90 (short-term)
SIP
°C
130
Autoclave
°C
130
Suction lift dry at optimum speed
Lift
m
2 at 1000 rpm
Volume specifications
Approximated volume per
revolution at free output
ml
91
Filling volume without
connectors
ml
~788
Residual volume (after idle
with high-speed motor)
ml
~6
Product wetted surface (approx.)
Surface
cm²
1586
Product wetted materials (standard):
Pump housing
1.4435
Valve plate
1.4435
Diaphragms
Santoprene
Valves
EPDM
O-rings