36
►
Remove the threaded pin (1 / PQ5G, item 2 Figure 13) from the
coupling half (2).
►
Disassemble the coupling half (2 / PQ5G, item 2 Figure 13).
►
Remove the screws (3 / PQ5A, item 4 Figure 8).
►
Turn the ring drive over.
►
Set down the ring drive so that there is no load on the shaft.
►
Replace the maintenance kit WLC unit (1).
►
Mount the assembly bolt (PQ5A, item 2 Figure 8) on the new unit.
►
Insert the new unit into the ring drive.
►
Fasten the first three screws (1 / PQ5A, item 4 Figure 8).
►
Unscrew the assembly bolt (2).
►
Fasten the last screw (1 / PQ5A, item 4 Figure 8).
►
Fasten the screws (3 / PQ5A, item 4 Figure 8).
►
Mount the coupling half (4 / PQ5G, item 2 Figure 13).
►
Fasten the coupling half with the threaded pin (5 / PQ5G, item 2 Figure
►
Align the coupling.
The end face of the shaft should be in line with the end face of the coupling
half if possible (red marking).