QUATRO
Air Technologies Inc.
3
12- ANNUAL GENERAL INSPECTION
Every 12 months, verify that all gaskets (seals) are in proper condition. Should the gaskets adhere to the filter, lubricate its surface with a transparent grease
or petroleum jelly. Should the unit be relocated continuously for optimum efficiency, ensure all casters (wheels) are tightly fastened and secure.
13- TROUBLESHOOTING GUIDE
Symptoms
Possible Cause
Suggested Solution
Unit will not start
Faulty Power supply
Return or supply grille blocked
HEPA filter improperly installed
Blown fuse
Unit not plugged into receptacle
Check breaker box
Remove obstruction
See Section 9, 10,11
Replace fuse
Plug unit in
Excessive noise
Motor wheel contacting inlet ring
Fan isolators loose or off
Realign/replace motor
Replace isolator
Insufficient airflow
Obstruction in system or clogged filters
Remove obstruction or replace filters
E
xcessive airflow
Filters not in place
Install filters
14- REDUCTION IN AIRFLOW
As the unit cleans the air, the filters are removing the particles of dust and dirt in the air. As the filters accumulate dirt (both visible and microscopic), a restriction on
the motor is created. As the restriction becomes greater, the air capacity delivered by the motor decreases and the air purification less effective. IT IS VERY
IMPORTANT TO CHANGE FILTERS ON A REGULAR BASIS (See filter maintenance above).
15- WARRANTY
QUATRO Air Technologies warrants its equipment to be free from defect in material and workmanship under normal use and service for a period of two year
from date of shipment. QUATRO's obligation under this warranty shall be limited to replacing any parts, thereof, which shall be demonstrated to have been
defective. This is expressly in lieu of all other warranties, express or implied, including the warranties of merchantability and fitness.
QUATRO claims no warranty as to merchantability or as to the fitness of the merchandise for any particular use and shall not be liable for any loss or damage.
No person, firm or corporation is authorised to assume for QUATRO any other liability in connection with the sale of these goods. Equipment, parts and
material manufactured by others and incorporated in QUATRO's equipment are warranted by QUATRO only to the extent of the original manufacturer's liability
to QUATRO Air Technologies Inc.
Conditions and Limitations:
This warranty does not cover
abuse, misuse, maintenance negligence, improper assembly, acts of vandalism, acts of God, fear wear, modifications of the
equipment or installation of a part not recommended by QUATRO Air Technologies, as well as operation of the equipment at voltages other than those
specified by QUATRO Air Technologies Inc.
16- SPARE PARTS
Qty
Description
Part
Qty
Description
Part
Qty
Description
Part
1
Fuse
E086
4
Fan Isolators
H454
4
Casters
H042
1
1/8" Gasket Roll (40')
H006
1
AF100 Motor, 120v
A014
1
Line cord-120v
E220
1
AF400 Motor, 120v
A001
1
AF100 Motor,230v
AB021
1
AF400 Motor, 230v
A035
1
Line cord (Std-230v)
E130