QUATRO
Air Technologies Inc.
2
6- FILTER MAINTENACE PROGRAM
Model
Unit Description
Filter Location
Filter Part No.
Description
Replacement Frequency
AF400D
High Capacity
Dust Air Purifier
Bottom
F071 (6/bx)
Dust Filter, MERV 8 rated
3 months
Middle
F073
Hi-Cap Filter, MERV 11 rated
12-15 months
Top
F475
HEPA Filter, 99.995% Efficient @0.3 microns
24-30 months
AF400DM
High Capacity
Dust/Odor
Air Purifier
Bottom
F071 (6/bx)
Dust Filter, MERV 8 rated
3 months
Middle
NC-GPC
Odor Granule refill
When odor detected
Top
F475
HEPA Filter, 99.995% Efficient @0.3 microns
24-30 months
AF100D
Lower Capacity
Low Noise
Dust Air Purifier
Bottom
F071 (6/bx)
Dust Filter, MERV 8 rated
3 months
Top
F475
HEPA Filter, 99.995% Efficient @0.3 microns
24-30 months
AF100DM
Lower Capacity
Low Noise
Dust/Odor Air Purifier
Bottom
F071 (6/bx)
Dust Filter, MERV 8 rated
3 months
Middle
NC-GPC
Odor Granule refill
When odor detected
Top
F074
HEPA Filter, 99.97% Efficient @0.3 microns
24-30 months
7- EQUIPMENT SPECIFICATIONS
Dimensions, Height:
AF400: 28.5” (724mm) AF100: 21” (533mm)
Voltage / Current
120/1/60 / 1.0amps
Dimensions, Width:
12.75” (324mm)
Max. Power Consumption:
85watts
Dimensions Length:
15.75” (400mm)
Approx. Weight:
48lbs (22kgs)
8- FILTER REPLACEMENT AF400
Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures ensuring the unit
will provide trouble-free operation for years to come. The purifier is designed to allow quick access to the filters, blower/motor and control panel assembly.
Bottom
DUST FILTER p/n F071
- Change the dust filter every three months (or more) depending on the dust level in the area;
- To do this, turn OFF the unit. Unplug from wall outlet, unscrew the (2) thumbscrews at the base of the unit;
- Remove the door, replace filter, ensure you close door prior tighten thumbscrews prior to operation;
Middle
Hi Capacity Filter p/n F073 (*AF400-D models, only)
- Change the HiCap filter every 12 to 16 months depending on the dust level in the area;
- To do this, turn OFF the unit. Unplug from wall outlet, unlatch the top section and remove;
- Pull out Stage II through the top. Replace with new Hi Capacity filter (make sure air flows are pointing up) Secure top back into position and both latches . The
airtight seal should be maintained.
Middle
Filter Tray Odor Granules (**AF400-DM models, only)
It is important the odor granules be replaced immediately upon any detection of odor from air purifier.
(odor granule, refill only, p/n F072-gpc)
To refill tray with new odor granules:
a)
Ensure that the unit is unplugged, unlatch top section and remove.
b)
Pull out filter tray and discard any remaining odor granules, refill with new odor granules.
c)
Put filter tray back into position (Stage II / middle). Secure top back into position and both latches. The airtight seal should be maintained.
Top
HEPA (p/n F475)
- Under typical applications, should last between 36 to 60 months (depending on applications);
- To do this, turn OFF the unit . Unplug from wall outlet. Unlatch the top section and remove;
- Pull out HEPA Filter from the top;
9- FILTER REPLACEMENT – AF100
Proper maintenance is critical to extend the life of the filtration system. The information presented below outlines basic maintenance procedures ensuring the unit
will provide trouble-free operation for years to come. The purifier is designed to allow quick access to the filters, blower/motor and control panel assembly.
Bottom
DUST FILTER p/n F071
- Change the dust filter every three months (or more) depending on the dust level in the area;
- To do this, turn OFF the unit. Unplug from wall outlet, unscrew the (2) thumbscrews at the base of the unit;
- Remove the door, replace filter, ensure you close door prior tighten thumbscrews prior to operation;
Middle
Filter Tray Odor Granules (**AF100DM models, only)
It is important the odor granules be replaced immediately upon any detection of odor from air purifier.
(odor granule, refill only, p/n F072-gpc)
To refill tray with new odor granules:
d)
Ensure that the unit is unplugged, unlatch top section and remove.
e)
Pull out filter tray and discard any remaining odor granules, refill with new odor granules.
f)
Put filter tray back into position (Stage II / middle). Secure top back into position and both latches. The airtight seal should be maintained.
Top
HEPA (p/n F475) FOR AF100D & F074 FOR AF100DM
- Under typical applications, should last between 36 to 60 months (depending on applications);
- To do this, turn OFF the unit . Unplug from wall outlet. Unlatch the top section and remove;
- Pull out HEPA Filter from the top;
10- SPEED CONTROL
- Dial in desired level of speed (Note: faster speeds provide superior levels of air purification)
11- MOTOR SERVICE
- The motor is brushless. No user motor maintenance is required .