6- FILTER MAINTENACE PROGRAM 

Model 

Unit Description 

Filter Location 

Filter Part No. 

Description 

Replacement Frequency 

AF400D 

High Capacity 

Dust Air Purifier 

Bottom 

F071 (6/bx) 

Dust Filter, MERV 8 rated

 

3 months

 

Middle

 

F073

 

Hi-Cap Filter, MERV 11 rated

 

12-15 months

 

Top 

F475 

HEPA Filter, 99.995% Efficient @0.3 microns

 

24-30 months

 

AF400DM 

High Capacity 

Dust/Odor 

Air Purifier 

Bottom 

F071 (6/bx) 

Dust Filter, MERV 8 rated

 

3 months

 

Middle

 

NC-GPC

 

Odor Granule refill

 

When odor detected

 

Top 

F475 

HEPA Filter, 99.995% Efficient @0.3 microns

 

24-30 months

 

 

 

 

 

 

 

AF100D 

Lower Capacity 

Low Noise 

Dust Air Purifier 

Bottom 

F071 (6/bx) 

Dust Filter, MERV 8 rated

 

3 months

 

Top 

F475 

HEPA Filter, 99.995% Efficient @0.3 microns

 

24-30 months

 

AF100DM 

Lower Capacity 

Low Noise 

Dust/Odor Air Purifier 

Bottom 

F071 (6/bx) 

Dust Filter, MERV 8 rated

 

3 months

 

Middle

 

NC-GPC

 

Odor Granule refill

 

When odor detected

 

Top 

F074 

HEPA Filter, 99.97% Efficient @0.3 microns

 

24-30 months

 

7- EQUIPMENT SPECIFICATIONS 

Dimensions, Height: 

AF400:  28.5” (724mm)    AF100: 21” (533mm) 

Voltage / Current 

120/1/60 / 1.0amps 

Dimensions, Width: 

12.75” (324mm) 

Max. Power Consumption: 

85watts 

Dimensions Length: 

15.75” (400mm) 

Approx. Weight: 

48lbs (22kgs) 

8- FILTER REPLACEMENT AF400 

Proper maintenance is critical to extend the life of the filtration system.  The information presented below outlines basic maintenance procedures ensuring the unit 
will provide trouble-free operation for years to come.  The purifier is designed to allow quick access to the  filters, blower/motor and control panel assembly. 

Bottom 

DUST FILTER p/n F071 

- Change the dust filter every three months (or more) depending on the dust level in the area; 
- To do this, turn OFF the unit.  Unplug from wall outlet, unscrew the (2) thumbscrews at the base of the unit; 
- Remove the door, replace filter, ensure you close door prior tighten thumbscrews prior to operation; 

Middle 

Hi Capacity  Filter p/n F073 (*AF400-D models, only) 

 

- Change the HiCap filter every 12 to 16 months depending on the dust level in the area; 
- To do this, turn OFF the unit.  Unplug from wall outlet, unlatch the top section and remove; 
- Pull out Stage II through the top.  Replace with new Hi Capacity filter (make sure air flows are pointing up) Secure top back into position and both latches .  The 
airtight seal should be maintained. 

Middle 

Filter Tray Odor Granules (**AF400-DM models, only) 

 

It is important the odor granules be replaced immediately upon any detection of odor from air purifier. 
(odor granule, refill only, p/n F072-gpc) 
To refill tray with new odor granules: 

a) 

Ensure that the unit is unplugged, unlatch top section and remove. 

b) 

Pull out filter tray and discard any remaining odor granules, refill with new odor granules. 

c) 

Put filter tray back into position (Stage II / middle).  Secure top back into position and both latches.  The airtight seal should be maintained. 

Top 

HEPA (p/n F475) 

  

- Under typical applications, should last between 36 to 60 months (depending on applications); 
- To do this, turn OFF the unit .  Unplug from wall outlet.  Unlatch the top section and remove; 
- Pull out HEPA Filter from the top; 

9- FILTER REPLACEMENT – AF100 

Proper maintenance is critical to extend the life of the filtration system.  The information presented below outlines basic maintenance procedures ensuring the unit 
will provide trouble-free operation for years to come.  The purifier is designed to allow quick access to the  filters, blower/motor and control panel assembly. 

Bottom 

DUST FILTER p/n F071 

- Change the dust filter every three months (or more) depending on the dust level in the area; 
- To do this, turn OFF the unit.  Unplug from wall outlet, unscrew the (2) thumbscrews at the base of the unit; 
- Remove the door, replace filter, ensure you close door prior tighten thumbscrews prior to operation; 

Middle 

Filter Tray Odor Granules (**AF100DM models, only) 

 

It is important the odor granules be replaced immediately upon any detection of odor from air purifier. 
(odor granule, refill only, p/n F072-gpc) 
To refill tray with new odor granules: 

d) 

Ensure that the unit is unplugged, unlatch top section and remove. 

e) 

Pull out filter tray and discard any remaining odor granules, refill with new odor granules. 

f) 

Put filter tray back into position (Stage II / middle).  Secure top back into position and both latches.  The airtight seal should be maintained. 

Top 

HEPA (p/n F475) FOR AF100D  & F074 FOR AF100DM 

- Under typical applications, should last between 36 to 60 months (depending on applications); 
- To do this, turn OFF the unit .  Unplug from wall outlet.  Unlatch the top section and remove; 
- Pull out HEPA Filter from the top; 

10- SPEED CONTROL 

- Dial in desired level of speed (Note: faster speeds provide superior levels of air purification) 

11- MOTOR SERVICE 

- The motor is brushless. No user motor maintenance is required . 