1- Using a ¼” socket, unscrew the 4 bolts holding down the motor 
2- Remove the motor WITH motor support bracket from the unit 
3- Separate motor from motor support bracket by unscrewing 4 screws 
4- Replace motor with new motor, and re-install as above 
(see Detailed Replacement instructions below) 

ALWAYS REPLACE BOTH MOTORS AT THE SAME TIME 

OR THE WEAR RATES OF THE BRUSHES WILL NEVER BE IN SYNC. 

Detailed Replacement 

1- Disconnect wires, cut zip ties.  
2- Remove the retaining nuts & lock washer holding the motor assemblies. 
3- Remove the motor retaining bracket from the old motor. Note the orientation on the bracket. 
4- Verify the gasket design (See the beginning of the Motor Service & Replacement Section) 
5- Install the bracket on the new motor. 

If the bracket is installed incorrectly it may result in a short to ground for the 

brush contacting the bracket. The curved brush must be visible in the large cutout as per Figure below 

6- Install the assembly back into the unit & connect the wires. Install new zip ties. 

On units equipped with iSeries controls reset the Service Motors(s) Alarm by following the instruction below. 
 
BLOWER MAINTENANCE 
WARNING: Switch unit off and unplug power cord from wall before servicing the blower.

 

LED Diagnostic Table - “Service Motor(s)” Alerts  
If “Service Filter(s)” alert is ON SOLID the motor(s) need to be serviced or replaced.  
MOTOR ACCESS:  The motor access panel is located below the unit.. 

 

 
 
Motor support brackets 
 
(4) screws holding motor to each bracket 
 
(8) Bolts holding down the 2 motors 

Motor is accessed from below the unit 

 
Motors installed in this device are rated for approximately 
20000 operating hours. 

Содержание CollectALL MedEVAC MultiPure PowerStation PS2

Страница 1: ...unit 6 ft long hose INSTALLATION 1 Open filter door remove plastic around HEPA filter and Odor Filter if applicable 2 Ensure filter bags are properly installed fit into 2 tubes beneath the top of fil...

Страница 2: ...companies shipping documents Single box c w all components required either on or inside the unit PRE START UP CHECKLIST a Check that all internal components are present and are adequately supported b...

Страница 3: ...t stops BEEPING 8 Led will be OFF and unit will be ready to operate again BLOWER MAINTENANCE INFINITY MOTORS NO BRUSH CHANGE REQUIRED This unit is equipped with an Automatic Motor Optimization System...

Страница 4: ...et design See the beginning of the Motor Service Replacement Section 5 Install the bracket on the new motor If the bracket is installed incorrectly it may result in a short to ground for the brush con...

Страница 5: ...r s Led stays SOLID 4 While motor is operating press hold SPEED UP DN simultaneously until unit BEEPS hold for 10 seconds when beeping continuously release 5 In this condition System ON Led is FLASHIN...

Страница 6: ...sed to assume for QUATRO any other liability in connection with the sale of these goods Equipment parts and material manufactured by others and incorporated in QUATRO s equipment are warranted by QUAT...

Страница 7: ...ming Urgent Replace Filters See Filter Service Replacement For More Info Continued Operation May Result In Unit Shutdown High Pressure Causes Excess Motor Heat Accelerates Brush Wear Flashing Slowly B...

Страница 8: ...n removed Remote has a shutdown delay of approximately 5 10 seconds Flashing None Unit is in Standby mode waiting for remote signal or mc2 signal if provided to start unit Low System Pressure Flashing...

Отзывы: