9.1 

SPEED CONTROL 

The unit is equipped with built-in speed control. By pressing & holding down the speed UP or DOWN triangles, you respectively increase and decrease 
unit’s speed.  When you reach the highest or lowest speed, the panel will continuously BEEP alerting you that you have reached the highest or lowest 
speed. 
 
 
 
Units that are equipped with factory optional Remote Control subD 9 pin connector can purchase an optional foot pedal switch (part# AA175 ) to 
turn unit on/off remotely. Also pins 1 and 2 can be wired to any dry contact switch for remote on/off capability. 
 
 
 

 

 
 
 

 

9.2 Replacement and optional components

 

 
 

10” collar plate for AF2000 

H184 

AF2000 HEPA seal rod kit (2) 

AR329-03 

AF2000 (120V) Fan 

AR329-02-16 

6” Collar plate for AF1000 

M701 

AF1000 HEPA seal rod kit (2) 

AR336-01 

AF1000 (120V) Fan 

A001-16 

8” Collar plate for AF1000 

M271-38 

Tube of removable sealant 

AR321 

120 volt power cord 

E220 

AF1000 grill plate (incl. 3 grills) 

AR336-02 

Single multi-directional grill 

H507 

AF2000 replacement grill 

H001 

 
 
 
 
 
 

Содержание AF Series

Страница 1: ...ntenance Keep all fastening hardware tight to ensure that the unit is in good working condition Familiarise yourself with the way in which filters are removed installed and serviced All filters must b...

Страница 2: ...ited if airflow is obstructed c Insert male end of cord into the correct voltage circuit Control will emit 3 beeps and 4 LEDs will flash along with those beeps d Press Power button and adjust airflow...

Страница 3: ...ust be taken not to damage the exposed portions of the new HEPA filter DO NOT bend aluminium separators as this will obstruct airflow j RESET Service Filter s Light see section 8 6 8 3 Optional CHEMIC...

Страница 4: ...ptimum efficiency ensure all casters are tightly fastened The motor is equipped with electric motor grade double shielded ball bearings and a special lubricant assuring long life and quiet operation N...

Страница 5: ...Remote Control subD 9 pin connector can purchase an optional foot pedal switch part AA175 to turn unit on off remotely Also pins 1 and 2 can be wired to any dry contact switch for remote on off capabi...

Страница 6: ...not plugged into receptacle o Check breaker box o Replace fuse o Plug unit in Excessive noise o Blower wheel contacting cone o Fan isolators loose or off o Realign replace wheel o Replace isolator Ins...

Страница 7: ...on system complete with adjustable inlet grill and adjustable discharge grills installed If it is desired to operate as a negative pressure system the 6 AF1000 or the 10 AF2000 discharge collars will...

Страница 8: ...he cutting drilling process If you decide not to replace the HEPA filter you must place something on top of the filter to protect against the metal shavings dropping into the filter Step 2 Remove the...

Страница 9: ...he unit Step 7 Use the self tapping screws to fix the plate on to the top of the unit permanently For units built with serial numbers greater than 75288 the 3 black grills will be mounted on a separat...

Страница 10: ...re is a kill switch that serves this function as an extra safety precaution Note UV C light bulbs should be replaced annually Visible blue light is not an indication of UV C output UV C wavelength is...

Страница 11: ...r cap counter clockwise and remove 4 Slide out the yellow safety latch 5 Twist the power supply counter clockwise and remove the UV light assembly 6 Loosen the clamp nut and remove the old UV C lightb...

Страница 12: ...alignment slots on the mounting ring allowing for an easy fit 9 Pull up on the yellow safety latch Turn the UV light assembly clock wise Note approx 60 degrees CW until installed Push down on the yel...

Отзывы: