Quatech, Inc. 

 

Airborne Enterprise Module Databook

 

 

26

 

7/15/2010 

100-8080-120

 

Command 

(Hex) 

Name 

Description 

0x40 

TXDATA 

The TXDATA command is used to send data to the module to 
be interpreted as commands if the module is in CLI mode, or to 
be transmitted on the wireless link if the module has an active 
data connection established.   

The host may send at most the number of bytes indicated by the 
TX Buffer Available field in the RX Message Header.  The actual 
number of bytes sent by the host is determined by the 16 bit 
value in PARM2.  The value in PARM2 is little-endian (LSB first) 
and must be less than or equal to the number in the TX Buffer 
Available field.  Any bytes sent in excess of this number will be 
ignored. 

PARM1 is unused for this command and should be set to zero. 

For example, to send the 

auth dpac dpac

 command, use the 

SPI message 0x40 0x00 0x0F 0x00 0x61 0x75 0x74 0x68 0x20 
0x64 0x70 0x61 0x63 0x20 0x64 0x70 0x61 0x63 0x0D.  That 
is, SPI command 0x40, PARM1 is 0x00, PARM2 is 0x000F, 
followed by the text for 

auth dpac dpac

.

 

0x80 

RXDATA 

The RXDATA command is used to receive data from the 
module.  In CLI mode, this data will be the local echoing of the 
commands issued to the module, as well as the command 
responses generated by the module.  If the module has an 
active data connection established, this data will be the data 
received on the wireless link.   

The host may receive at most the number of bytes indicated by 
the RX Data Available field in the RX Message Header.  The 
actual number of bytes received by the host is determined by 
the 16 bit value in PARM2.  The value in PARM2 is little-endian 
(LSB first) and must be less than or equal to the number in the 
RX Data Available field.  If additional clock cycles are sent to the 
module beyond this number, meaningless data will be returned. 

PARM1 is unused for this command and should be set to zero.

 

The TXDATA and RXDATA commands can be combined for full-duplex 
operation.  For example, a command byte of 

0xC0

 would be a TXDATA and 

RXDATA command combined.  The result of this command would be that the 
module would accept data being shifted in as TX data, while at the same time, 
RX data would be shifted out.  In this case, the number of bytes transferred for 
TXDATA must be equal to the number of bytes transferred for RXDATA.  The 
PARM2 parameter will indicate the number of bytes to be transferred for both the 
TXDATA and RXDATA commands. 

Содержание 802.11B/G

Страница 1: ...Product Specification 802 11b g High Performance Enterprise Device Server Revision 1 2 July 2010 File name databook wlng dp500 family v1 2 doc Document Number 100 8080 120...

Страница 2: ...Quatech Inc Airborne Enterprise Module Databook 2 7 15 2010 100 8080 120 Page Intentionally Left Blank...

Страница 3: ...The reader remains responsible for the system design and for ensuring that the overall system satisfies its design objectives taking due account of the information presented herein the specifications...

Страница 4: ...Quatech Inc Airborne Enterprise Module Databook 4 7 15 2010 100 8080 120 Page Intentionally Left Blank...

Страница 5: ...racteristics Transmitter 19 6 2 Performance Range 19 7 0 SPI Interface 21 7 1 Pinout 21 7 2 SPI AC Characteristics 22 7 3 SPI Protocol 23 7 4 SPI Commands 24 8 0 Antenna 27 8 1 Antenna Selection 27 8...

Страница 6: ...Pin Definition 11 Table 3 UART Pin Definition 13 Table 4 Absolute Maximum Values 1 16 Table 5 Operating Conditions DC Specification 16 Table 6 RF Characteristics 802 11b g 18 Table 7 Supported Data Ra...

Страница 7: ...following convention will be used The area next to the indicator will identify the specific information and make any references necessary The area next to the indicator will identify the specific inf...

Страница 8: ...ver TCP IP stack UDP telnet FTP server Data bridging and buffering Command Line Interface Web interface WPA Supplicant 802 11 Radio Driver Supports antenna diversity Operating Temperature 40 C to 85 C...

Страница 9: ...Airborne Enterprise Module Databook Quatech Inc 100 8080 120 7 15 2010 9 3 0 Block Diagram The following outlines the block diagram of the radio Figure 2 WLNG SE SP AN ET DP500 Block Diagram...

Страница 10: ...th RS232 422 485 Driver Control l l l l l l l l l l WLNG SP DP501 802 11b g SPI Interface l l l l l l l l WLNG AN DP501 802 11b g UART Interface l l l l l l l l l l WLNG ET DP501 802 11b g 10 100 Ethe...

Страница 11: ...RXD All DIN Debug 9 RXD2 UART DIN UART2 RXD2 Serial DIN UART2 RXD2 SPI DIN UART2 RXD2 Ethernet DIN UART2 G6 All GPIO 10 TDO All JTAG Test data out 11 FRESET All Factory RESET 12 CTS1 UART Clear to Sen...

Страница 12: ...tion Indicator F6 GPIO 24 RXD1 UART DIN UART1 RXD1 Serial DIN UART1 MOSI SPI DIN SPI RXD1 Ethernet DIN UART1 F7 All GPIO 25 LED_POST All POST Status Indicator F0 GPIO 26 LED_WLN_CFG All Module TCP IP...

Страница 13: ...to a 2 wire only The primary digital UART can be used as the primary connection for the Serial device type This type supports a 7 wire interface to allow the definition of the serial interface type RS...

Страница 14: ...er It is recommended that a connection to this port be supported via test points or a two pin header The default settings for the debug port are 115200 8 N 1 No Flow Control CAUTION Do not use the deb...

Страница 15: ...ors to the radio J1 36 pin Digital Host interface Hirose DF12 36DP 0 5V XX 0 50mm 020 Pitch Plug Surface Mount Dual Row Vertical 4 00mm Stack Height 36 Circuits J2 Primary RF connector for 802 11b g a...

Страница 16: ...age 2 0 VDD 0 3 VOL Output Low Level Voltage 0 4 VOH Output High Level Voltage VDD 0 4 ICCTXG Operating Current UART Data In 802 11g Transmitting 54Mb s UART 100 Duty Cycle 920K BAUD 340 360 mA ICCRXG...

Страница 17: ...nd CPU on No data traffic UART 340 360 mA ICCE Radio and CPU on No data traffic Ethernet 330 350 mA ISBU0 Radio off UART CPU Idle radio off f w control 350 360 mA ISBE0 Radio off Ethernet CPU Idle rad...

Страница 18: ...ak dBm mW Units POUTB Transmit Power Output 802 11b 11 5 5 2 1 13 15 31 6 19 3 85 1 dBm mW POUTG Transmit Power Output 802 11g 6 9 12 18 24 36 48 54 10 12 15 9 21 5 141 3 dBm mW PRSENB Receive Sensiti...

Страница 19: ...02 11g US Canada 2 401 2 473 11 1 11 Europe 2 401 2 483 13 1 13 France 2 446 2 483 4 10 13 Japan 2 401 2 483 13 1 13 1 Only channels 1 6 and 11 are non overlapping 6 1 AC Electrical Characteristics Tr...

Страница 20: ...135m 215m 6Mb s 802 11a 49m 155m 54Mb s 802 11g 12m 19m 54Mb s 802 11a 4 5m 14m Ranges are based on receiver sensitivity Transmitter power free space path loss estimates antenna gain factors and link...

Страница 21: ...ve Out MISO 28 Master Out Slave In MOSI 24 SPI Interrupt SPI_INT 22 SPI Clock SPI_CLK 18 SPI Select SPI_SEL 12 Data In RxD2 DTXD 9 8 Data out TxD2 DRXD 21 6 Ready to Send RTS2 17 Clear to Send CTS2 19...

Страница 22: ...C Timings Symbol Parameter Min Typ Max Units fMAX Maximum Clock Frequency 8 00 MHz tCS SPI Select Low to Clock Rising Edge 100 ns tCH Clock High 62 5 ns tCL Clock Low 62 5 ns tDA Clock High to Data Ou...

Страница 23: ...s of the TX message header The RX message header consists of a RX Data Available field and a TX Buffer Available field The RX Data Available field indicates the number of data bytes the Device Server...

Страница 24: ...e BREAK command will issue a break sequence to the module It is analogous to the BREAK signal on a common UART Use this command to issue a BREAK if the esc mode serial brk setting is configured in the...

Страница 25: ...st has received all the RX data available from the module All other bits of PARM1 are unused for this command and should be set to zero PARM2 is unused for this command and should be set to zero For e...

Страница 26: ...e module In CLI mode this data will be the local echoing of the commands issued to the module as well as the command responses generated by the module If the module has an active data connection estab...

Страница 27: ...Host Chassis mounted antenna Embedded antenna In addition to the above options location and performance need to be considered the following sections discuss these items 8 2 Host Board Mounted Antenna...

Страница 28: ...ulk head mounting there are no connector choice restrictions for use with the FCC IOC modular certification However if the flying lead connector is used the same restrictions as identified for the Hos...

Страница 29: ...system using this approach maybe slightly more complex since the antenna is not necessarily mounted on the host PCBA 8 5 Antenna Location The importance of this design choice cannot be over stressed...

Страница 30: ...ermine the link rate generally as the link quality for a given link rate drops below a predefined limit the radio will drop to the next lowest link rate and try to communicate using it The reciprocal...

Страница 31: ...ee Path Loss dB RxS Receiver receive sensitivity dBm RxA Receiver antenna gain dBi RxC Receiver to Antenna coax cable loss dB This is a complex subject and requires more information than is presented...

Страница 32: ...following timing and signal conditions Figure 5 Power on RESET Timing Figure 6 RESET Timing Table 17 RESET Timing Symbol Parameter Min Typ Max Units tPURST Valid VDD to RESET valid 200 ms tRLRV RESET...

Страница 33: ...Where control of the RESET signal by system level monitor is not possible Quatech recommend the use of the circuit in Figure 7 or one similar This circuit controls the RESET signal relative to power...

Страница 34: ...Tolerance 1 27 0 05 unless noted 40 60 1 60 MAX 30 70 1 21 MIN 1 84 0 07 12 37 0 49 MAX 29 60 1 17 MAX 18 27 0 72 MIN 15 90 0 63 3X 1 00 0 04 3X 2 00 0 08 Part Hirose DF12 36DS 0 5V Not available for...

Страница 35: ...Stack Height 36 Circuits Board Connector DF12 36DP 0 5V XX Hirose Hirose 0 50mm 020 Pitch Plug Surface Mount Dual Row Vertical 4 00mm Stack Height 36 Circuits RF Connector U FL Hirose Ultra Small Surf...

Страница 36: ...ructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interfe...

Страница 37: ...rne WLN modules the customers are relieved of any need to perform FCC part15 subpart C Intentional Radiator testing and certification except where they wish to use an antenna that is not already certi...

Страница 38: ...ve any concerns regarding the hardware integration Contact Quatech Technical support for a copy of the FCC and IOC grant certificates the test reports and updated approved antenna list 11 5 Regulatory...

Страница 39: ...tive humidity cycle Altitude Sect 4 8 Operational 0 12 000ft 62 KPa absolute pressure Non operational 0 40 000ft 18 6 KPa absolute pressure Vibration Sect 4 9 Operational 2 4 Grms 10 1K Hz 1hr per axi...

Страница 40: ...tion 5 3 SPI interface section 6 0 Table 4 0 Changed maximum voltage to 4 0VDC Table 5 0 Updated Power state labels and values 7 0 Added section 7 0 SPI interface specification 11 5 Added reference to...

Отзывы: