Compact RDMS
TM
Telemetry Receiver
19
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
*VF
Viterbi Forget
Factor
Report or set the Viterbi
forget factor, on a scale from
0.01 – 0.99
Examples:
VF Report the Viterbi
forget factor
VF 0.04 Set the Viterbi
forget factor to 0.04
VF 0.62 Set the Viterbi
forget factor to 0.62
Standard
Advanced
Command
PCM/FM
VL
Verbosity
Level
Report or set verbosity level,
on a scale of 0 – 9
Examples:
VL Report the verbosity
level
VL 0 Set the verbosity level
to 0
VL 5 Set the verbosity level
to 5
Standard
Advanced
Command
None
ZZ Show
Options
Displays the current
hardware configuration and
options on the receiver
Standard
Advanced
Command
None
*Note regarding VF command:
The VF command sets the observation window for the Viterbi decoder in the
trellis demod. The longer the window, the more coding gain. The smaller the window, the more resistant to phase
noise. Quasonix recommends NOT manually changing this value. The Phase Noise Compensation mode
automatically adjusts this as needed.