Compact RDMS
TM
Telemetry Receiver
15
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
PL
Input Power
Level
Reports or sets the current
input power level setting
Examples:
PL
Report the current
input power level information
tracking state
PL 0
Set the current
power level information
tracking display to OFF
PL 1
Set the current
power level information
tracking display to ON
PL reports the Input signal
level of the receiver, the
signal level into the demod,
the digitally scaled signal
level, the SNR, and eb/N0
Standard
Advanced
Command
None
PN
Phase Noise
Compensation
Report or set phase noise
compensation state
Examples:
PN Report the phase
noise compensation state
PN 0 Set phase noise
compensation to OFF
PN 1 Set phase noise
compensation to ON
Standard Basic
PCM/FM
PR
Reset
Defaults for
Currently
Selected
Mode
Restores factory default
parameters for the currently
selected mode on the unit
Refer to Appendix E for a list
of factory default values by
mode
Standard
Advanced
Command
None
QT
Query
Temperature
Report the temperature in
degrees Celsius
Standard Basic
None