Compact RDMS
TM
Telemetry Receiver
9
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Basic or
Advanced
Command
Mode
Restriction
CP Clock
Polarity
Report or set clock polarity
inversion state
Examples:
CP
Report the clock
source state
CP 0
Set clock inversion
OFF
CP 1
Set clock inversion
ON
Standard Basic
For Asynch
PSK
(legacy)
modes, CP
A and CP
B must be
specified
separately
DE
Differential
Decoder
Enable
Report or set differential
decoding
Examples:
DE Report
the
differential decoding
setting
DE 0
Set differential
decoding OFF
DE 1
Set differential
decoding ON
Standard Basic
SOQPSK
DP Data
Polarity
Report or set data polarity
inversion state
Examples:
DP
Display the current
data polarity
DP 0
Set data polarity to
NOT inverted (OFF)
DP 1
Set data polarity to
inverted (ON)
Standard Basic
For Asynch
PSK
(legacy)
modes, DP
A and DP
B must be
specified
separately
FL
Force Lock
Indication
Diagnostic tool to force the
system to indicate locked or
unlocked status; primarily
used to verify wiring setup
Examples:
FL
Show the force lock
state
FL 1
Force lock to ON
FL 0
Force lock to Normal
FL -1
Force lock to OFF
Standard
Advanced
Command
None