3
rd
Generation Dual Channel
Compact RDMS
TM
Telemetry Receiver-Combiner
76
Quasonix, Inc.
Figure 107: BERT, BERT Measurement Drop Down Menu
•
(Re)Start BERT – Starts (or restarts) the (BER) test measurement with an error count and total bit count of
zero; indicates whether a measurement is currently running or stopped
Figure 108: BERT, ReStart BERT Button
•
Pattern – Sets the data pattern used by the bit error rate test; This may be a fixed pattern or a pseudorandom
pattern that repeats based on the chosen pattern/sequence (a shorter pattern looks more regular, a longer
pattern looks more random)
•
PN6 – Pseudorandom pattern 2
6
-1 bits in length
•
PN9 – Pseudorandom pattern 2
9
-1 bits in length
•
PN11 – Pseudorandom pattern 2
11
-1 bits in length
•
PN15 – Pseudorandom pattern 2
15
-1 bits in length
•
PN17 – Pseudorandom pattern 2
17
-1 bits in length
•
PN20 – Pseudorandom pattern 2
20
-1 bits in length
•
PN23 – Pseudorandom pattern 2
23
-1 bits in length
•
PN31 – Pseudorandom pattern 2
31
-1 bits in length
•
User Defined
•
User Defined – A unique binary pattern, between 2 and 32 bits, specified by the person running
the test; only available when Pattern is “User Defined”