A 3-pin alarm terminal provides external alarm indication. The alarm signal conforms to SMPTE 269M
Standard for fault reporting in television systems. This requires that the user connect an external fault
indicator and power supply to the alarm terminals. The power supply should be 24 VDC max. and current
limited to 20mA (See SMPTE 269M for further details). The pin-out for the Alarm connector is shown
below:
The alarm connector will only function correctly if the main and backup processors are configured correctly
with information about what modules are installed in the router. Refer to Appendix 1 for details of the Telnet
‘piset’ (Product Inventory Set) command.