PSU Configuration and Monitoring
LightSpeed Appliances Getting Started Guide | 63
PSU Configuration and Monitoring
These are the supported PSU configurations for the appliance models and PSU types:
PSU Type
QLS250
QLS450, QLS650, and QLS800
MLS200 and MLS400
AC or DC
2 PSUs
3 PSUs
2 PSUs
Important - All PSUs on an appliance must be of the same type, either all AC or all DC.
When a PSU functions correctly: the PSU LED is green, the Alert LED does not blink due to a PSU issue
(might blink due to other errors), and there is no SNMP alarm.
When a PSU does not function correctly: the PSU LED is amber, the Alert LED blinks due to a PSU issue,
and an SNMP alarm is sent.
To monitor the PSUs on the appliance in Gaia Clish:
1. Connect to the command line on the appliance.
2. Log in to Gaia Clish.
3. Run:
show sysenv ps
Example output on a QLS800 appliance:
QLS800> show sysenv ps
Hardware Information
Name
Value
Unit
Type
Status
Maximum
Minimum
Power Supply #1
Up
Up/Down
Power
0
Up
Down
Power Supply #2
Up
Up/Down
Power
0
Up
Down
Power Supply #3
Dummy
Up/Down
Power
0
Up
Down
Where:
Column
Description
Name
Power Supply #1
- The PSU in the top PSU slot.
Power Supply #2
- The PSU in the middle PSU slot.
Power Supply #3
- The PSU in the bottom PSU slot.
Value
Up
- The PSU slot contains a PSU and is up.
Down
- The PSU slot contains a PSU that is not connected to a power source.
Empty
- The PSU slot is empty.
Dummy
- The PSU slot contains a dummy filler.
Unit
Up/Down
- The type of measure unit used for PSUs is either Up or Down.
Type
Power
- The type of the sensor.