background image

 

 DX3000 and DX5000 Quick Start Guide

2

Choosing a Location

0

The DX3000/DX5000 must be installed in a restricted access 
location per specification

 EN69050-1.

 This system must only 

be installed by qualified IT service personnel. This is required 
to prevent untrained personnel from allowing body parts or 
electrically conductive items to penetrate into the interior of 
the system when replacing or installing drives, fans, and 
power supplies. 
When choosing an installation site for the DX3000/DX5000 
system, consider the following requirements:

Rack Space Requirements

Environmental Conditions

Rack Space Requirements

0

Table 1

 contains the rack requirements for both the DX3000 

and DX5000.

Table 1   Rack Requirements

Environmental Conditions

0

The installation site must have the following environmental 
conditions:

Humidity: 20%-80% non-condensing

Temperature: 10°C-35°C (50°F-95°F)

Altitude: 0 to 10,000 feet (0 to 3048 meters)

These environmental conditions apply when the DX-Series 
system is in operation.

DX3000

DX5000

Depth

27 in (68.6 cm)

25.4 in (64.5 cm)

Width

19 in (48.3 cm)

19 in (48.3 cm)

Height

3.5 in (8.9 cm), 

2U

8.75 (22.2 cm), 5U

Weight

50 lbs (22.68 kg)

122 (55.34 kg)

Air 
Clearance

Open 4 in (10.2 cm) behind unit for proper 

air flow

N

OTE

:

For additional specifications, refer to the 

Quantum DX3000 and DX5000 User’s Guide

 (PN 

81-81493)

Preparing for the Installation

0

Before you begin the installation procedure in this section, 
make the following preparations as described in this 
section:

Providing Necessary Tools

Taking ESD Precautions

Providing Necessary Tools 

0

Provide the following tools for unpacking and installing the 
DX3000 and DX5000 systems:

#1 PHILLIPS® screwdriver

#2 PHILLIPS screwdriver

#1 Flat head screwdriver

Antistatic wrist strap included in accessory kit

Taking ESD Precautions

0

Some components within the DX3000 and DX5000 systems 
contain static-sensitive parts. To avoid damaging these parts 
while performing installation procedures, always observe 
the following precautions:

Keep the DX3000/DX5000 system turned off during all 
installation procedures.

Use an antistatic wrist strap (included in the accessory 
kit).

Keep static-sensitive parts in their original shipping 
containers until ready for installation.

Do not place static-sensitive parts on a metal surface. 
Place them inside their protective shipping bag or on an 
antistatic mat.

Avoid touching connectors and other components.

Unpacking the DX3000/DX5000

0

This section explains how to unpack both the DX3000 and 
DX5000 system components and move them to their final 
installation location.
By following these instructions, you help ensure that the 
system will continue to be safeguarded after it arrives at the 
installation site.

N

OTE

:

Dry climates and cold-weather heating 

environments have lower relative humidity and 
are more likely to produce static electricity.

Содержание DX3000

Страница 1: ...tial Configuration 8 Introduction 0 This quick start guides provides basic installation and configuration instructions for both the DX3000 and DX5000 systems see figure 1 For more information see the...

Страница 2: ...81493 Preparing for the Installation 0 Before you begin the installation procedure in this section make the following preparations as described in this section Providing Necessary Tools Taking ESD Pr...

Страница 3: ...am Foam Quick start Cables Hard drive sleds Rail kit Antistatic bag Lift point Figure 3 Unpacking the DX5000 Installing the DX3000 DX5000 System 0 Installing the DX3000 5000 in a rack consists of the...

Страница 4: ...f mounting hardware on the rack rails Ensure that any necessary mounting hardware is installed on the rack rails prior to installing the chassis Clip nut Installing the DX3000 DX5000 Chassis 0 1 Assem...

Страница 5: ...short brackets pre installed DX5000 Adjustment screws adjusts to the depth of your rack DX5000 Front mounting bracket preset Ensure the screws are in the correct position DX5000 rack rails DX3000 rac...

Страница 6: ...lbs 38 56 kg without hard drives Two people are required to lift either unit Chassis mounting holes Chassis mounting holes DX5000 support bracket DX3000 support bracket Figure 8 Securing the DX3000 DX...

Страница 7: ...ive 2 Drive 3 Drive 4 Drive 5 Drive 6 Drive 7 Drive 8 Drive 9 Drive 10 Drive 11 Array controller 2 Array controller 1 Drive 0 Drive 1 Drive 4 Drive 6 Drive 7 Drive 5 Figure 10 Installing the Disk Driv...

Страница 8: ...pply cables Ethernet ports Fibre Channel ports optional Optyon cards 1 2 Configuring the DX3000 DX5000 consists of the following major steps Accept the License Agreement Complete the User Registration...

Страница 9: ...see figure 16 NOTE If you do not accept the license agreement the DX3000 DX5000 will not function Figure 16 User Registration 5 The registration information is sent to Quantum to allow the system to...

Страница 10: ...of 255 255 255 0 The default IP address for port 2 is 10 0 1 0 with a netmask of 255 255 0 0 NOTE Refer to the Quantum DX3000 and DX5000 User s Guide PN 81 81493 for additional network configuration...

Страница 11: ...Drives 11 Select the volume s either All Volumes or Volume Name where the tape cartridges will be created 12 Create cartridges by either quantity or capacity If you select By quantity you can create b...

Отзывы: