Installing the Motor Assembly
3
Route the belt connecting the counterweight and the carriage over
the guide roller and past the motor/pulley belt retainer on the
motor assembly (see
).
Figure 11 Routing the Belt
4
Connect the ribbon cable from the vertical shuttle assembly to the
socket on the control board at the rear of the motor assembly as
shown in
:
a
Route the ribbon cable behind the motor plate.
b
Insert the ribbon cable connector through the rectangular hole
at the top of the motor plate.
c
Connect the ribbon cable connector to the socket on the control
board.
Figure 12 Connecting the
Ribbon Cable
Ribbon cable
Motor plate
Rectangular hole