background image

QE7018 

INSTALLATION INSTRUCTIONS 

 

 

 

ALL ELECTRICAL WORK SHOULD BE CARRIED OUT BY A COMPETENT ELECTRICIAN 

 

 

1  Decide on a suitable location. 

 

2  Mark the position for the 2 No.8 Woodscrews. (supplied) 

 

3  Fit the screws leaving the screws protruding 15mm from the wall.  

 

4  Mark the position on the wall for the 13A Fused Spur connection. 

 

5  Install the fused spur back box and supply cable. (Surface mount or sunken)  

 

6  Mount the heater on to the 2 off No.8 Woodscrews. 

 

7  Ensure that the mains supply is turned off. 

 

8  Connect the supply to the fused spur front plate. 

 

9  Connect the unit to the front plate as described below. 

 

10  Replace the front plate. 

 

11  Installation is now complete. 

 
CONNECTION DETAILS 
 

THIS UNIT MUST BE CONNECTED TO THE MAINS SUPPLY BY A SWITCHED FUSED SPUR 

FITTED WITH A 10A FUSE 

 

The wires in the cable attached to this unit are coloured in accordance with the following code:- 

 

 

  BLUE 

============= 

NEUTRAL 

 

  BROWN 

=============

 

LIVE

 

 

 

This unit does not require an earth wire as the case is Double Insulated. 

 
As the colour may not correspond with the markings indentifying the terminals in the fused  
spur proceed as follows. 
 

 

Blue wire must be connected to the terminal marked ‘N LOAD’ 

 

Brown wire must be connected to the terminal marked ‘L LOAD’ 

 

 

 
 

Содержание QE-7018

Страница 1: ...box should also contain the following items The most important item is a QE 7018 wall heater 1 off Remote control 2 off No8 Woodscrews 35 mm long 2 off plastic Rawlplugs for fixing the heater to a concrete or brick wall If there is anything missing please call 05602 045420 between 8 00am and 4 00pm Mon to Fri and we will do our best to replace the items as soon as possible or you can email us at s...

Страница 2: ...ect the supply to the fused spur front plate 9 Connect the unit to the front plate as described below 10 Replace the front plate 11 Installation is now complete CONNECTION DETAILS THIS UNIT MUST BE CONNECTED TO THE MAINS SUPPLY BY A SWITCHED FUSED SPUR FITTED WITH A 10A FUSE The wires in the cable attached to this unit are coloured in accordance with the following code BLUE NEUTRAL BROWN LIVE This...

Страница 3: ...e TIMER RIGHT HAND button This steps the time up by hour with each press To turn off the unit switch off the FUSED SPUR FROM THE REMOTE CONTROL The remote control requires two AAA batteries not supplied To switch the appliance on from the STANDBY mode press the RED button on the remote control The unit will switch on in the FAN only mode Pressing the 1000W button will select the low heat setting P...

Страница 4: ...terial Curtains Drapes Bedding etc when in use Do not use in the immediate vicinity of bathtubs showers wash basins or swimming pools Do not use outdoors Do not use this appliance for other than its intended purpose This appliance is for interior use only Do not attempt to repair disassemble or modify the appliance in any way There are no user serviceable parts inside Do not insert or allow to be ...

Отзывы: