TPA-MHL-8R - Quick Start Guide
68-00224 - Rev. A4
Page 25
August 31, 2011
Use the procedure below to make the connections for running the compliance tests on an MHL
sink device.
1. Apply power to the TPA-MHL-8R using the power adapter provided.
2. Make the connections as shown in the diagram below. For this application you will be using
the section on the TPA-MHL-8R labeled
882 CONNECTIONS
– SINK DUT
.
a. Connect an MHL cable from the MHL sink device under test to the MHL OUT TO DUT
connector on the TPA-MHL-8R.
b. Connect an HDMI cable from the HDMI IN connector of the TPA-MHL-8R to the HDMI
OUT port on the 882E.
3. Refer to the 980 User Guide for details on how to use the MHL compliance test application
to run compliance tests on an MHL sink.
Connect MHL
cable to MHL
HDTV (MHL sink)
Connect HDMI
cable to the
HDMI Out Port
of the 882EA
Analyzer