TPA-MHL-8R - Quick Start Guide
68-00224 - Rev. A4
Page 14
August 31, 2011
4. Optionally, if you wish to monitor the C-Bus transactions while monitoring the MHL stream
make the following connections and refer to the diagram that follows as a reference:
a. Connect an MHL cable from the MHL source device under test to the MHL IN FROM
SOURCE connector on the section of the TPA-MHL-8R labeled
980 CONNECTIONS
–
CBUS ANALYSIS
.
b. Connect a Coax cable from the connector labeled TO 980 TRIGGER IN CBUS on the
section of the TPA-MHL-8R labeled to
980 CONNECTIONS
– CBUS ANALYSIS
to the
BNC connector labeled TRIG IN on the 980 Protocol Analyzer.
c.
Connect a second MHL cable from the MHL OUT TO SINK connector on the section of
the TPA-MHL-8R labeled
980 CONNECTIONS
– CBUS ANALYSIS
to the MHL IN
FROM DUT connector on the section of the TPA-MHL-8R labeled
980 CONNECTIONS
– SOURCE DUT
.
d. Connect an HDMI cable from the connector labeled OUT TO 980 PORT 1 on the
section of the TPA-MHL-8R labeled
980 CONNECTIONS
– SOURCE DUT
to the Rx
port on the 980 Protocol Analyzer.