COMMUNICATIONS PROTOCOL
Cubiscan 325 command set
CubiScan 325 Service Manual
67
Scale reading
This command causes the Cubiscan 325 to report the measured weight of objects on the scale.
This can be used to verify if the scale is empty.
Pos
Len
Description
Type
Range
ASCII
Command format
1
1
Start of text
Control
(STX)
02h
2
1
Build command
Alpha
(s)
673h
3
1
End of text
Control
(ETX)
03h
4
1
Carriage return
Control
(CR)
0Dh
5
1
Line feed
Control
(LF)
0Ah
Acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Build command
Alpha
(s)
73h
3
1
Acknowledge
Alpha
(A)
41h
4
1
Weight identifier
Alpha
(K)
4Bh
5
6
Weight
Numeric
00.000-99.999
11
1
Comma
Alpha
(,)
2Ch
12
2
Wgt. Dim. wgt unit
Alpha
(lb/kg)
14
1
End of text
Control
(ETX)
03h
15
1
Carriage return
Control
(CR)
0Dh
16
1
Line feed
Control
(LF)
0Ah
Negative acknowledge format
1
1
Start of text
Control
(STX)
02h
2
1
Build command
Alpha
(s)
73h
3
1
Neg. acknowledge
Alpha
(N)
4Eh
4
1
End of text
Control
(ETX)
03h
5
1
Carriage return
Control
(CR)
0Dh
6
1
Line feed
Control
(LF)
0Ah