Communication Protocol
CubiScan 125 Command Set
CubiScan 125 Service Manual
6 1
* This field may contain underscores, dashes, or overscores indicating an under, unstable, or over
error condition, respectively.
33
1
Dimension Unit
Alpha
(E/M)
45h or 4Dh
34
1
Comma
Alpha
(,)
2Ch
35
1
Weight Identifier
Alpha
(K)
4Bh
36
6
Weight
Numeric
000.00-999.99*
42
1
Comma
Alpha
(,)
2Ch
43
1
Dim. Wgt. Identifier
Alpha
(D)
44h
44
6
Dim. Weight
Numeric
000.00-999.99*
50
1
Comma
Alpha
(,)
2Ch
51
1
Wgt./Dim.Wgt Unit
Alpha
(E/M)
45h or 4Dh
52
1
Comma
Alpha
(,)
2Ch
53
1
Factor Identifier
Alpha
(F)
46h
54
4
Factor
Numeric
0000-9999
58
1
Comma
Alpha
(,)
2Ch
59
1
Domestic/Int'l. Unit
Alpha
(D/I)
44h or 49h
60
1
End of Text
Control
(ETX)
03h
61
1
Carriage Return
Control
(CR)
0Dh
62
1
Line Feed
Control
(LF)
0Ah
Negative Acknowledge Format
1
1
Start of Text
Control
(STX)
02h
2
1
Measure Command
Alpha
(M)
4Dh
3
1
Neg. Acknowledge
Alpha
(N)
4Eh
4
1
CubiScan/Host
Originated
Alpha
(C/H)
43h or 48h
5
1
Corner Sensor / Measure
/ Zero Error
Alpha
(C/M/Z)
43h or 4Dh
or 5Ah
6
1
End of Text
Control
(ETX)
03h
7
1
Carriage Return
Control
(CR)
0Dh
8
1
Line Feed
Control
(LF)
0Ah
Pos Len
Description
Type
Range
ASCII