- 8 -
With factory default settings the jumper is located on the central and
uppermost pins, in which case the display shows the currently meas-
ured room temperature value, while the notice “
ROOM
” appears in the
bottom right corner of the display. In this case, the adjusted tempera-
ture is visible only during the adjustment process, for approximately 7
seconds after the last button has been pushed. By relocating the plug
onto the bottommost and central pins the displayed temperature can
be modified so that the display alternately shows the current room tem
-
perature and the adjusted temperature for 4 seconds, respectively. In
this mode, the notices “
ROOM
” and “
SET
” are alternately shown under
the currently displayed temperature in the bottom right corner of the
display, indicating whether the display shows the room temperature or
the adjusted temperature value.
3.2 Selecting the Switching Sensitivity (Accuracy)
The switching sensitivity of the thermostat can be selected or adjusted
by the central jumper.
With factory default settings the jumper is located on the central
and uppermost pins, resulting in a switching sensitivity of ±0.2 °C.
It can be modified to ±0.1 °C by relocating the jumper onto the
bottommost and central pins. A smaller switching sensitivity re-
sults in steadier room temperature and therefore in higher comfort.