![Quantrax COMPUTHERM Q5RF Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/quantrax/computherm-q5rf/computherm-q5rf_operating-instructions-manual_3465111017.webp)
- 17 -
COMPUTHERM
Q5RF
(TX)
thermostat:
• Separate the back panel of thermostat
COMPUTHERM
Q5RF(TX)
from the front panel by pushing the latch located on
the upper side of the case.
• Press and hold buttons „
LEARN
” and „
RESET
” located inside
the thermostat smultaneously.
• Release the „
RESET
” button and keep the „
LEARN
” button de-
pressed for additional 5 seconds.
• Following this, sign
U1
appears on the display of the thermo-
stat, indicating that the thermostat can now be synchronized
with zone 1 of the receiving unit.
• If a lettering other than
U1
appears on the display of the thermo-
stat, select zone 1 with the help of buttons
and
.
• Press and hold the „
LEARN
” button located inside the
thermostat for approx. 3 seconds until the green LED on the
COMPUTHERM
Q1RX
plug stops flashing.
After the two units have been synchronized, the thermostat con-
trols the plug according to the temperature program having been
set. When the thermostat is switched on, 230 V, 50 Hz mains volt-
age appears on the output socket of the plug.