- 12 -
positions of the switch a different tempera-
ture can be set between 5 °C and 40 °C, in
steps of 0.5 °C.
For energy efficiency it is recommended that the comfort tem-
perature is only used those times, when the room or building
is in use, because every 1 °C decrease of temperature saves
approximately 6% energy during a heating season. As opposed
to common belief, keeping a flat warn requires more energy than
heating it up. (When using a stove, more gas is needed to keep
a pan of water boiling than to just keep it warm.)
The factory default temperature is 18 °C for the economy (
w
)
position and 20 °C for the comfort (
☼
) position. These default
temperatures can be changed as follows:
•
Move the switch according to the temperature you would
like to change (economy (
w
) or comfort (
☼
)).
•
Press the
or
button, after which the notice
“
ROOM
” disappears, the notice “
SET
” (adjusted value) ap-
pears in the bottom right corner of the display. Meanwhile,
the temperature value shown on the display switches from
room temperature to the default temperature (18.0 °C/20.0
°C) or to the last set temperature (this temperature is blink-
ing on the display). By pressing the buttons repeatedly or