QuantAsylum QA451 User’s Manual

 

 

 

 

Page 2 

 

 

 

 

Product Notice 

The QA451 and QA451B are the same product, using the same software. There is a difference in current 
sensing accuracy between the two products used on the DC  Sense port. This port is for use in 
measuring the current consumption of an amplifier board. On the QA451B product, the resolution is 10-
20 mA, while on the QA451 product the resolution is 5-10 mA.  

Throughout this document, the QA451 reference should be taken to mean the QA451 and QA451B 
products. Differences between the products, if any, will be noted.  

Safety Notice 

 

This device is not designed for working on potentially dangerous voltages. 

 

This device is not designed for working on high energy circuits. 

 

Know and understand the voltage and current limits for each input 

 

See additional safety notices throughout this document. 

Limited Warranty 

This product has a limited warranty for 6 months from the time of purchase. During this time, a device 
failure that occurs under normal operating conditions will be replaced or repaired for free, not including 
shipping. Generally, you will be responsible for shipping to us, and we will be responsible for shipping it 
back to you.  

Devices that have suffered a failure due to operation in excess of specified parameters can usually be 
repaired for a nominal fee. 

The contents of this document are provided “as

-

is” and may be changed or updated without notice. The 

specifications on a particular product may also be changed at any time and without notice as we seek to 
improve a product or improve availability of a product. 

The limit of our warranty will not exceed the value of the product purchased under any conditions. 

 

 

Содержание QA451

Страница 1: ...QuantAsylum QA451 User s Manual Page 1 QuantAsylum QA451 B User s Manual Programmable 4 8 Ohm Load SW Release 1 4 October 2023...

Страница 2: ...and the voltage and current limits for each input See additional safety notices throughout this document Limited Warranty This product has a limited warranty for 6 months from the time of purchase Dur...

Страница 3: ...uts 7 DUT Power Soft Start 7 Load Inputs 8 BNC Outputs 8 QA451 Software 9 Application Temperature Sensing 10 Application Current Sensing 10 DUT Power 10 Fault Conditions 10 Remote Connections 10 QA451...

Страница 4: ...QuantAsylum QA451 User s Manual Page 4 Tractor 19...

Страница 5: ...are electrically isolated from the USB grounds This isolation is limited to 50V Do not connect the QA451 to a product that has its ground reference more than 50V from the PC ground Current Sense Input...

Страница 6: ...high side PMOS switch Power handling up to 300W duration limited Current limiting of supply for accidental shorts trips when 15A for more than 2mS Soft start allowing gentle turn on of the amplifier D...

Страница 7: ...o be used For example if you are testing Class D amplifier boards it might make sense to use the current sense and power the boards from a fixed external supply But if you are testing finished amplifi...

Страница 8: ...not exceed the 200W for 220 mS rating of the Amplifier Load subsystem BNC Outputs The BNC outputs are single ended attenuated version of the load inputs The attenuation is 12 dB This means if your amp...

Страница 9: ...us bar we can see the hardware device is opened and that this is firmware version 30 You will be alerted if the firmware version is incorrect and given a chance to re flash the QA451 hardware It is im...

Страница 10: ...system The resolution is around 5 to 10 mA That is you will see readings jump by perhaps 5 mA On the QA451B the resolution is around 10 to 20 mA For high power amplifiers that might draw 10A or so thi...

Страница 11: ...s port 9450 opened then run the QA451 application with admin rights and see if that allows a browser to open the link above If that solves the problem then you can either run the app with admin rights...

Страница 12: ...to handle 25W when the case temperature is 25C That 25W figure is de rated by about 15 as the backplate temperature reaches 50C If the resistors are near room temperature and the QA451 is configured f...

Страница 13: ...ility of the QA401 and QA451 combine to allow thorough testing at high power levels The QA451 is obviously not the platform you d chose for burning in amplifiers But a test suite that has an average p...

Страница 14: ...on the switch contact us at the support alias and we can work to help solve the problem Thermal Considerations The QA451 is NOT designed for sinking 10 s of watts for long periods of time The QA451 c...

Страница 15: ...ge power drops to 1 5W In summary you need to plan your thermal budget ahead of time to ensure the QA451 can meet your needs Hitting the thermal targets above will ensure continuous operation without...

Страница 16: ...QuantAsylum QA451 User s Manual Page 16 Appendix I Typical Connection Diagram...

Страница 17: ...itch is on S will be equal to S The switch is not bidirectional If S exceeds S then current will begin to flow through the MOSFET body diode 2 Soft start is provided to allow power supplies with large...

Страница 18: ...QuantAsylum QA451 User s Manual Page 18...

Страница 19: ...nput Gain option on the QA401 This is how you tell the QA401 application that the value it is measuring is less than the actual value and thus the reported peaks and noise for example must be increase...

Страница 20: ...QuantAsylum QA451 User s Manual Page 20...

Отзывы: