C
ONNECTORS
AND
J
UMPERS
C
ONNECTORS
AND
J
UMPERS
5-2
Mainboard Jumpers
L
OCATION
J
UMPER
P
OSITIONS
F
UNCTION
D
EFAULT
S
ETTING
CMOS CLEAR
J29
1-2
Normal RTC
RST
V
2-3
CLR RTC Reg-
isters
PASSWORD CLEAR
J32
1-2
Normal Opera-
tion
V
2-3
Clear Pass-
words
ME FIRMWARE UPDATE JUMPER
J28
1-2
Normal Mode
V
ME IN Force
Update Mode
BMC DISABLE JUMPER
J18
1-2
Disable BMC
NC
Normal
V
REAR COM PORT SWITCH JUMPER
J14
1-2
COM Port
Switch to BMC
NC
Normal (sys-
tem)
V
BIOS RECOVERY JUMPER
J34
1-2
Normal (sys-
tem)
V
2-3
Reset BIOS to
Deafult Settings
POWER BUTTON SKIPPING BMC JUMPER
Note:
Shorting J24 is not effective if BMC is functioning properly.
J24
1-2
Directly Enable
Power Skip
BMC
NC
Normal (sys-
tem)
V